A comparative study between paired and unpaired Image Quality Assessment in Low-Dose CT Denoising
Not on the map. Why?
Abstract (arXiv)
The current deep learning approaches for low-dose CT denoising can be divided into paired and unpaired methods. The former involves the use of well-paired datasets, whilst the latter relaxes this constraint. The large availability of unpaired datasets has raised the interest in deepening unpaired denoising strategies that, in turn, need for robust evaluation techniques going beyond the qualitative evaluation. To this end, we can use quantitative image quality assessment scores that we divided into two categories, i.e., paired and unpaired measures. However, the interpretation of unpaired metrics is not straightforward, also because the consistency with paired metrics has not been fully investigated. To cope with this limitation, in this work we consider 15 paired and unpaired scores, which we applied to assess the performance of low-dose CT denoising. We perform an in-depth statistical analysis that not only studies the correlation between paired and unpaired metrics but also within each category. This brings out useful guidelines that can help researchers and practitioners select the right measure for their applications.
Key facts. Cited by 6 papers in the map (data through 14 Oct 2026). Builds on 6 of its 23 references that are in the map. First posted on arXiv 11 Apr 2023.
Builds on
6 of 23 references.
References · 6
- 2018The Unreasonable Effectiveness of Deep Features as a Perceptual Metriccited by 11,177
- 2018Demystifying MMD GANscited by 1,293
- 2017Low-Dose CT with a Residual Encoder-Decoder Convolutional Neural Network (RED-CNN)cited by 224
- 2019From Patches to Pictures (PaQ-2-PiQ): Mapping the Perceptual Space of Picture Qualitycited by 223
- 2017Low Dose CT Image Denoising Using a Generative Adversarial Network with Wasserstein Distance and Perceptual Losscited by 162
- 2016Low-dose CT denoising with convolutional neural networkcited by 18
Built on by
Citing papers per year: 2024: 1; 2025: 2; 2026: 3.
6 papers.
- 2024Multi-Scale Texture Loss for CT denoising with GANscited by 2
- 2025Texture-Aware StarGAN for CT data harmonisationcited by 1
- 2025Sample-Aware Test-Time Adaptation for Medical Image-to-Image Translationcited by 1
- 2026Cross Modality Image Translation In Medical Imaging Using Generative Frameworkscited by 1
- 2026A Systematic Benchmark of GAN Architectures for MRI-to-CT Synthesiscited by 0
- 20263D CT-to-PET Translation via Latent Brownian Bridge Diffusioncited by 0
- 20263D CT-to-PET Translation via Latent Brownian Bridge Diffusion11 Sep 2026
- 2026Cross Modality Image Translation In Medical Imaging Using Generative Frameworks13 May 2026
- 2026A Systematic Benchmark of GAN Architectures for MRI-to-CT Synthesis13 Mar 2026
- 2025Sample-Aware Test-Time Adaptation for Medical Image-to-Image Translation1 Aug 2025
- 2025Texture-Aware StarGAN for CT data harmonisation19 Mar 2025
- 2024Multi-Scale Texture Loss for CT denoising with GANs25 Mar 2024