mlsanityData to 7 Oct 2026

Cellular EXchange Imaging (CEXI): Evaluation of a diffusion model including water exchange in cells using numerical phantoms of permeable spheres

arXiv 2303.16112 ↗First posted 28 Mar 2023eess.SP physics.med-phcited by 1

On the map: Diffusion models → Medical imaging and segmentation

Abstract (arXiv)

Purpose: Biophysical models of diffusion MRI have been developed to characterize microstructure in various tissues, but existing models are not suitable for tissue composed of permeable spherical cells. In this study we introduce Cellular Exchange Imaging (CEXI), a model tailored for permeable spherical cells, and compares its performance to a related Ball & Sphere (BS) model that neglects permeability. Methods: We generated DW-MRI signals using Monte-Carlo simulations with a PGSE sequence in numerical substrates made of spherical cells and their extracellular space for a range of membrane permeability. From these signals, the properties of the substrates were inferred using both BS and CEXI models. Results: CEXI outperformed the impermeable model by providing more stable estimates cell size and intracellular volume fraction that were diffusion time-independent. Notably, CEXI accurately estimated the exchange time for low to moderate permeability levels previously reported in other studies (kappa<25μ m/s). However, in highly permeable substrates (kappa=50μ m/s), the estimated parameters were less stable, particularly the diffusion coefficients. Conclusion: This study highlights the importance of modeling the exchange time to accurately quantify microstructure properties in permeable cellular substrates. Future studies should evaluate CEXI in clinical applications such as lymph nodes, investigate exchange time as a potential biomarker of tumor severity, and develop more appropriate tissue models that account for anisotropic diffusion and highly permeable membranes.

Key facts. Cited by 1 paper in the map (data through 7 Oct 2026). Placed in Medical imaging and segmentation, one of 14 directions in Diffusion models. Builds on 2 of its 66 references that are in the map. First posted on arXiv 28 Mar 2023.

Builds on

2 of 66 references.

References · 2

  1. 2016Rotationally-invariant mapping of scalar and orientational metrics of neuronal microstructure with diffusion MRIcited by 8
  2. 2019Robust Monte-Carlo Simulations in Diffusion-MRI: Effect of the substrate complexity and parameter choice on the reproducibility of resultscited by 1

Built on by

Cited by year (2026 to 7 Oct)

Citing papers per year: 2026: 1.

1 paper.

Similar, not cited

Close in wording, no citation either way

  1. 2024X-Diffusion: Generating Detailed 3D MRI Volumes From a Single Image Using Cross-Sectional Diffusion Models
  2. 2024Diff5T: Benchmarking Human Brain Diffusion MRI with an Extensive 5.0 Tesla K-Space and Spatial Dataset
  3. 2024Denoising diffusion models for high-resolution microscopy image restoration
  4. 2023A Survey of Emerging Applications of Diffusion Probabilistic Models in MRI
  5. 2025Computationally Efficient Diffusion Models in Medical Imaging: A Comprehensive Review
  6. 2025Adapting Video Diffusion Models for Time-Lapse Microscopy
  7. 2025DEMIST: Decoupled Multi-stream latent diffusion for Quantitative Myelin Map Synthesis
  8. 2024QSMDiff: Unsupervised 3D Diffusion Models for Quantitative Susceptibility Mapping