Image Enhancement for Remote Photoplethysmography in a Low-Light Environment
Not on the map. Why?
Abstract (arXiv)
With the improvement of sensor technology and significant algorithmic advances, the accuracy of remote heart rate monitoring technology has been significantly improved. Despite of the significant algorithmic advances, the performance of rPPG algorithm can degrade in the long-term, high-intensity continuous work occurred in evenings or insufficient light environments. One of the main challenges is that the lost facial details and low contrast cause the failure of detection and tracking. Also, insufficient lighting in video capturing hurts the quality of physiological signal. In this paper, we collect a large-scale dataset that was designed for remote heart rate estimation recorded with various illumination variations to evaluate the performance of the rPPG algorithm (Green, ICA, and POS). We also propose a low-light enhancement solution (technical solution) for remote heart rate estimation under the low-light condition. Using collected dataset, we found 1) face detection algorithm cannot detect faces in video captured in low light conditions; 2) A decrease in the amplitude of the pulsatile signal will lead to the noise signal to be in the dominant position; and 3) the chrominance-based method suffers from the limitation in the assumption about skin-tone will not hold, and Green and ICA method receive less influence than POS in dark illuminance environment. The proposed solution for rPPG process is effective to detect and improve the signal-to-noise ratio and precision of the pulsatile signal.
Key facts. Cited by 22 papers in the map (data through 7 Oct 2026). Builds on 4 of its 33 references that are in the map. First posted on arXiv 16 Mar 2023.
Builds on
4 of 33 references.
References · 4
- 2015Staple: Complementary Learners for Real-Time Trackingcited by 60
- 2018VIPL-HR: A Multi-modal Database for Pulse Estimation from Less-constrained Face Videocited by 57
- 2017A Reproducible Study on Remote Heart Rate Measurementcited by 49
- 2019iPhys: An Open Non-Contact Imaging-Based Physiological Measurement Toolboxcited by 8
Built on by
Citing papers per year: 2023: 1; 2024: 5; 2025: 7; 2026: 9.
22 papers.
Sort:
By area:
- 2024Advancing Generalizable Remote Physiological Measurement through the Integration of Explicit and Implicit Prior Knowledgecited by 13
- 2025PHASE-Net: Physics-Grounded Harmonic Attention System for Efficient Remote Photoplethysmography Measurementcited by 10
- 2024PhysMLE: Generalizable and Priors-Inclusive Multi-task Remote Physiological Measurementcited by 9
- 2024Bi-TTA: Bidirectional Test-Time Adapter for Remote Physiological Measurementcited by 6
- 2025Remote Photoplethysmography in Real-World and Extreme Lighting Scenarioscited by 6
- 2024Resolve Domain Conflicts for Generalizable Remote Physiological Measurementcited by 4
- 2025Align the GAP: Prior-based Unified Multi-Task Remote Physiological Measurement Framework For Domain Generalization and Personalizationcited by 4
- 2026FreqPhys: Repurposing Implicit Physiological Frequency Prior for Robust Remote Photoplethysmographycited by 3
- 2024Continual Learning for Remote Physiological Measurement: Minimize Forgetting and Simplify Inferencecited by 2
- 2025Sage Deer: A Super-Aligned Driving Generalist Is Your Copilotcited by 2
- 2026PhysNeXt: Next-Generation Dual-Branch Structured Attention Fusion Network for Remote Photoplethysmography Measurementcited by 2
- 2023Remote Bio-Sensing: Open Source Benchmark Framework for Fair Evaluation of rPPGcited by 1
10 more
- 2026rPPG-VQA: A Video Quality Assessment Framework for Unsupervised rPPG Trainingcited by 1
- 2026PhysFlow: Frequency Decoupled with Dual-Field Rectified Flow for Remote Photoplethysmographycited by 1
- 2026PhysAgent: A Multi-Agent Framework for Reliable Remote Heart Rate Estimationcited by 1
- 2025Period-LLM: Extending the Periodic Capability of Multimodal Large Language Modelcited by 0
- 2025Exploring Remote Physiological Signal Measurement under Dynamic Lighting Conditions at Night: Dataset, Experiment, and Analysiscited by 0
- 2025FedHUG: Federated Heterogeneous Unsupervised Generalization for Remote Physiological Measurementscited by 0
- 2026SVC 2026: the Second Multimodal Deception Detection Challenge and the First Domain Generalized Remote Physiological Measurement Challengecited by 0
- 2026RPM-Distill: Physiology-guided Adaptive Cross-modal Distillation for Robust Remote Physiological Measurementcited by 0
- 2026PhysVR: Vision-Language Model Guided Interference-aware Temporal Feature Refinement for Remote Physiological Measurementcited by 0
- 2026FLOW: Feature-Level Optimal Warping for Generalized Remote Physiological Measurementcited by 0
- 2026FLOW: Feature-Level Optimal Warping for Generalized Remote Physiological Measurement30 Sep 2026
- 2026PhysVR: Vision-Language Model Guided Interference-aware Temporal Feature Refinement for Remote Physiological Measurement30 Aug 2026
- 2026PhysAgent: A Multi-Agent Framework for Reliable Remote Heart Rate Estimation29 Jul 2026
- 2026RPM-Distill: Physiology-guided Adaptive Cross-modal Distillation for Robust Remote Physiological Measurement26 Jun 2026
- 2026PhysFlow: Frequency Decoupled with Dual-Field Rectified Flow for Remote Photoplethysmography22 Jun 2026
- 2026rPPG-VQA: A Video Quality Assessment Framework for Unsupervised rPPG Training13 Apr 2026
- 2026SVC 2026: the Second Multimodal Deception Detection Challenge and the First Domain Generalized Remote Physiological Measurement Challenge7 Apr 2026
- 2026FreqPhys: Repurposing Implicit Physiological Frequency Prior for Robust Remote Photoplethysmography1 Apr 2026
- 2026PhysNeXt: Next-Generation Dual-Branch Structured Attention Fusion Network for Remote Photoplethysmography Measurement20 Mar 2026
- 2025FedHUG: Federated Heterogeneous Unsupervised Generalization for Remote Physiological Measurements14 Oct 2025
- 2025PHASE-Net: Physics-Grounded Harmonic Attention System for Efficient Remote Photoplethysmography Measurement29 Sep 2025
- 2025Exploring Remote Physiological Signal Measurement under Dynamic Lighting Conditions at Night: Dataset, Experiment, and Analysis6 Jul 2025
10 more
- 2025Align the GAP: Prior-based Unified Multi-Task Remote Physiological Measurement Framework For Domain Generalization and Personalization19 Jun 2025
- 2025Period-LLM: Extending the Periodic Capability of Multimodal Large Language Model30 May 2025
- 2025Sage Deer: A Super-Aligned Driving Generalist Is Your Copilot15 May 2025
- 2025Remote Photoplethysmography in Real-World and Extreme Lighting Scenarios14 Mar 2025
- 2024Bi-TTA: Bidirectional Test-Time Adapter for Remote Physiological Measurement25 Sep 2024
- 2024Continual Learning for Remote Physiological Measurement: Minimize Forgetting and Simplify Inference19 Jul 2024
- 2024PhysMLE: Generalizable and Priors-Inclusive Multi-task Remote Physiological Measurement10 May 2024
- 2024Resolve Domain Conflicts for Generalizable Remote Physiological Measurement11 Apr 2024
- 2024Advancing Generalizable Remote Physiological Measurement through the Integration of Explicit and Implicit Prior Knowledge11 Mar 2024
- 2023Remote Bio-Sensing: Open Source Benchmark Framework for Fair Evaluation of rPPG24 Jul 2023
- 2024Advancing Generalizable Remote Physiological Measurement through the Integration of Explicit and Implicit Prior Knowledgecited by 13
- 2025PHASE-Net: Physics-Grounded Harmonic Attention System for Efficient Remote Photoplethysmography Measurementcited by 10
- 2024PhysMLE: Generalizable and Priors-Inclusive Multi-task Remote Physiological Measurementcited by 9
- 2024Bi-TTA: Bidirectional Test-Time Adapter for Remote Physiological Measurementcited by 6
- 2025Remote Photoplethysmography in Real-World and Extreme Lighting Scenarioscited by 6
- 2024Resolve Domain Conflicts for Generalizable Remote Physiological Measurementcited by 4
- 2025Align the GAP: Prior-based Unified Multi-Task Remote Physiological Measurement Framework For Domain Generalization and Personalizationcited by 4
- 2026FreqPhys: Repurposing Implicit Physiological Frequency Prior for Robust Remote Photoplethysmographycited by 3
- 2024Continual Learning for Remote Physiological Measurement: Minimize Forgetting and Simplify Inferencecited by 2
- 2025Sage Deer: A Super-Aligned Driving Generalist Is Your Copilotcited by 2
- 2026PhysNeXt: Next-Generation Dual-Branch Structured Attention Fusion Network for Remote Photoplethysmography Measurementcited by 2
- 2023Remote Bio-Sensing: Open Source Benchmark Framework for Fair Evaluation of rPPGcited by 1
12 most cited of 21 All 21 (JSON)
- 2026FLOW: Feature-Level Optimal Warping for Generalized Remote Physiological Measurement30 Sep 2026
- 2026PhysVR: Vision-Language Model Guided Interference-aware Temporal Feature Refinement for Remote Physiological Measurement30 Aug 2026
- 2026PhysAgent: A Multi-Agent Framework for Reliable Remote Heart Rate Estimation29 Jul 2026
- 2026RPM-Distill: Physiology-guided Adaptive Cross-modal Distillation for Robust Remote Physiological Measurement26 Jun 2026
- 2026PhysFlow: Frequency Decoupled with Dual-Field Rectified Flow for Remote Photoplethysmography22 Jun 2026
- 2026rPPG-VQA: A Video Quality Assessment Framework for Unsupervised rPPG Training13 Apr 2026
- 2026SVC 2026: the Second Multimodal Deception Detection Challenge and the First Domain Generalized Remote Physiological Measurement Challenge7 Apr 2026
- 2026FreqPhys: Repurposing Implicit Physiological Frequency Prior for Robust Remote Photoplethysmography1 Apr 2026
- 2026PhysNeXt: Next-Generation Dual-Branch Structured Attention Fusion Network for Remote Photoplethysmography Measurement20 Mar 2026
- 2025FedHUG: Federated Heterogeneous Unsupervised Generalization for Remote Physiological Measurements14 Oct 2025
- 2025PHASE-Net: Physics-Grounded Harmonic Attention System for Efficient Remote Photoplethysmography Measurement29 Sep 2025
- 2025Exploring Remote Physiological Signal Measurement under Dynamic Lighting Conditions at Night: Dataset, Experiment, and Analysis6 Jul 2025
12 newest of 21 All 21 (JSON)