mlsanityData to 7 Oct 2026

Need for Objective Task-based Evaluation of Deep Learning-Based Denoising Methods: A Study in the Context of Myocardial Perfusion SPECT

arXiv 2303.02110 ↗First posted 3 Mar 2023eess.IV cs.CV cs.LGcited by 3

Not on the map. Why?

Abstract (arXiv)

Artificial intelligence-based methods have generated substantial interest in nuclear medicine. An area of significant interest has been using deep-learning (DL)-based approaches for denoising images acquired with lower doses, shorter acquisition times, or both. Objective evaluation of these approaches is essential for clinical application. DL-based approaches for denoising nuclear-medicine images have typically been evaluated using fidelity-based figures of merit (FoMs) such as RMSE and SSIM. However, these images are acquired for clinical tasks and thus should be evaluated based on their performance in these tasks. Our objectives were to (1) investigate whether evaluation with these FoMs is consistent with objective clinical-task-based evaluation; (2) provide a theoretical analysis for determining the impact of denoising on signal-detection tasks; (3) demonstrate the utility of virtual clinical trials (VCTs) to evaluate DL-based methods. A VCT to evaluate a DL-based method for denoising myocardial perfusion SPECT (MPS) images was conducted. The impact of DL-based denoising was evaluated using fidelity-based FoMs and AUC, which quantified performance on detecting perfusion defects in MPS images as obtained using a model observer with anthropomorphic channels. Based on fidelity-based FoMs, denoising using the considered DL-based method led to significantly superior performance. However, based on ROC analysis, denoising did not improve, and in fact, often degraded detection-task performance. The results motivate the need for objective task-based evaluation of DL-based denoising approaches. Further, this study shows how VCTs provide a mechanism to conduct such evaluations using VCTs. Finally, our theoretical treatment reveals insights into the reasons for the limited performance of the denoising approach.

Key facts. Cited by 3 papers in the map (data through 7 Oct 2026). Builds on 13 of its 72 references that are in the map. First posted on arXiv 3 Mar 2023.

Builds on

13 of 72 references.

References · 13

  1. 2015Deep Residual Learning for Image Recognitioncited by 51,809
  2. 2014Adam: A Method for Stochastic Optimizationcited by 36,960
  3. 2015U-Net: Convolutional Networks for Biomedical Image Segmentationcited by 19,604
  4. 2017Low-Dose CT with a Residual Encoder-Decoder Convolutional Neural Network (RED-CNN)cited by 224
  5. 2017Low Dose CT Image Denoising Using a Generative Adversarial Network with Wasserstein Distance and Perceptual Losscited by 161
  6. 2017Compressed Sensing MRI Reconstruction using a Generative Adversarial Network with a Cyclic Losscited by 82
  7. 2021Assessing the Impact of Deep Neural Network-based Image Denoising on Binary Signal Detection Taskscited by 20
  8. 2021Objective task-based evaluation of artificial intelligence-based medical imaging methods: Framework, strategies and role of the physiciancited by 15
  9. 2019Deep Learning for Low-Dose CT Denoisingcited by 14
  10. 2021Impact of deep learning-based image super-resolution on binary signal detectioncited by 9
  11. 2021Deep neural networks-based denoising models for CT imaging and their efficacycited by 6
  12. 2017A Cascaded Convolutional Neural Network for X-ray Low-dose CT Image Denoisingcited by 5
1 more
  1. 2022Investigating the limited performance of a deep-learning-based SPECT denoising approach: An observer-study-based characterizationcited by 3

Built on by

Cited by year

Citing papers per year: 2023: 1; 2024: 1; 2025: 1.