Abstract (arXiv)

Recently, remote respiratory rate measurement techniques gained much attention as they were developed to overcome the limitations of device-based classical methods and manual counting. Many approaches for RR extraction from the video stream of the visible light camera were proposed, including the pixel intensity changes method. In this paper, we propose a new method for 1D profile creation for pixel intensity changes-based method, which significantly increases the algorithm's performance. Additional accuracy gain is obtained via a new method of motion signals grouping presented in this work. We introduce several changes to the standard pipeline, which enables real-time continuous RR monitoring and allows applications in the human-computer interaction systems. Evaluation results on two internal and one public datasets showed 0.7 BPM, 0.6 BPM, and 1.4 BPM MAE, respectively.

Key facts. No citing papers in the map yet (data through 14 Oct 2026). Builds on 5 of its 18 references that are in the map. First posted on arXiv 21 Nov 2022.

Builds on

5 of 18 references.

References · 5

  1. 2019MediaPipe: A Framework for Building Perception Pipelinescited by 583
  2. 2017A Reproducible Study on Remote Heart Rate Measurementcited by 51
  3. 2021Algorithmic Principles of Camera-based Respiratory Motion Extractioncited by 6
  4. 2021Dual Attention Network for Heart Rate and Respiratory Rate Estimationcited by 2
  5. 2020Mid-Air Haptic Bio-Holograms in Mixed Realitycited by 1

Built on by

Not cited yet.