Instantaneous Physiological Estimation using Video Transformers
Not on the map. Why?
Abstract (arXiv)
Video-based physiological signal estimation has been limited primarily to predicting episodic scores in windowed intervals. While these intermittent values are useful, they provide an incomplete picture of patients' physiological status and may lead to late detection of critical conditions. We propose a video Transformer for estimating instantaneous heart rate and respiration rate from face videos. Physiological signals are typically confounded by alignment errors in space and time. To overcome this, we formulated the loss in the frequency domain. We evaluated the method on the large scale Vision-for-Vitals (V4V) benchmark. It outperformed both shallow and deep learning based methods for instantaneous respiration rate estimation. In the case of heart-rate estimation, it achieved an instantaneous-MAE of 13.0 beats-per-minute.
Key facts. Cited by 5 papers in the map (data through 7 Oct 2026). Builds on 13 of its 30 references that are in the map. First posted on arXiv 24 Feb 2022.
Builds on
13 of 30 references.
References · 13
- 2017Attention Is All You Needcited by 59,932
- 2020An Image is Worth 16x16 Words: Transformers for Image Recognition at Scalecited by 29,915
- 2020End-to-End Object Detection with Transformerscited by 7,384
- 2020End-to-End Human Pose and Mesh Reconstruction with Transformerscited by 417
- 2021Video Transformer Networkcited by 271
- 2018DeepPhys: Video-Based Physiological Measurement Using Convolutional Attention Networkscited by 153
- 2020Multi-Task Temporal Shift Attention Networks for On-Device Contactless Vitals Measurementcited by 133
- 2020Video-based Remote Physiological Measurement via Cross-verified Feature Disentanglingcited by 78
- 2021The Way to my Heart is through Contrastive Learning: Remote Photoplethysmography from Unlabelled Videocited by 66
- 2020Towards Inheritable Models for Open-Set Domain Adaptationcited by 64
- 2021TransRPPG: Remote Photoplethysmography Transformer for 3D Mask Face Presentation Attack Detectioncited by 41
- 2021The First Vision For Vitals (V4V) Challenge for Non-Contact Video-Based Physiological Estimationcited by 19
1 more
Built on by
Citing papers per year: 2023: 3; 2024: 0; 2025: 1; 2026: 1.
5 papers.
- 2023PhysFormer++: Facial Video-based Physiological Measurement with SlowFast Temporal Difference Transformercited by 46
- 2023rPPG-MAE: Self-supervised Pre-training with Masked Autoencoders for Remote Physiological Measurementcited by 37
- 2023Remote Heart Rate Monitoring in Smart Environments from Videos with Self-supervised Pre-trainingcited by 1
- 2025Contactless Cardiac Pulse Monitoring Using Event Camerascited by 0
- 2026Non-Contact Physiological Monitoring in Pediatric Intensive Care Units via Adaptive Masking and Self-Supervised Learningcited by 0
- 2026Non-Contact Physiological Monitoring in Pediatric Intensive Care Units via Adaptive Masking and Self-Supervised Learning17 Feb 2026
- 2025Contactless Cardiac Pulse Monitoring Using Event Cameras14 May 2025
- 2023Remote Heart Rate Monitoring in Smart Environments from Videos with Self-supervised Pre-training23 Oct 2023
- 2023rPPG-MAE: Self-supervised Pre-training with Masked Autoencoders for Remote Physiological Measurement4 Jun 2023
- 2023PhysFormer++: Facial Video-based Physiological Measurement with SlowFast Temporal Difference Transformer7 Feb 2023