mlsanityData to 7 Oct 2026

Spatio-Temporal Deep Learning-Based Undersampling Artefact Reduction for 2D Radial Cine MRI with Limited Data

arXiv 1904.01574 ↗First posted 1 Apr 2019eess.IV cs.LG stat.MLcited by 14

Not on the map. Why?

Abstract (arXiv)

In this work we reduce undersampling artefacts in two-dimensional (2D) golden-angle radial cine cardiac MRI by applying a modified version of the U-net. We train the network on 2D spatio-temporal slices which are previously extracted from the image sequences. We compare our approach to two 2D and a 3D Deep Learning-based post processing methods and to three iterative reconstruction methods for dynamic cardiac MRI. Our method outperforms the 2D spatially trained U-net and the 2D spatio-temporal U-net. Compared to the 3D spatio-temporal U-net, our method delivers comparable results, but with shorter training times and less training data. Compared to the Compressed Sensing-based methods kt-FOCUSS and a total variation regularised reconstruction approach, our method improves image quality with respect to all reported metrics. Further, it achieves competitive results when compared to an iterative reconstruction method based on adaptive regularization with Dictionary Learning and total variation, while only requiring a small fraction of the computational time. A persistent homology analysis demonstrates that the data manifold of the spatio-temporal domain has a lower complexity than the spatial domain and therefore, the learning of a projection-like mapping is facilitated. Even when trained on only one single subject without data-augmentation, our approach yields results which are similar to the ones obtained on a large training dataset. This makes the method particularly suitable for training a network on limited training data. Finally, in contrast to the spatial 2D U-net, our proposed method is shown to be naturally robust with respect to image rotation in image space and almost achieves rotation-equivariance where neither data-augmentation nor a particular network design are required.

Key facts. Cited by 14 papers in the map (data through 7 Oct 2026). First posted on arXiv 1 Apr 2019.

Builds on

No reference list yet.

Built on by

Cited by year

Citing papers per year: 2021: 2; 2022: 4; 2023: 4; 2024: 3; 2025: 1.

14 papers.

Sort:

  1. 2021AI-based Reconstruction for Fast MRI -- A Systematic Review and Meta-analysiscited by 38
  2. 2023Global k-Space Interpolation for Dynamic MRI Reconstruction using Masked Image Modelingcited by 8
  3. 2023Unsupervised reconstruction of accelerated cardiac cine MRI using Neural Fieldscited by 8
  4. 2021An End-To-End-Trainable Iterative Network Architecture for Accelerated Radial Multi-Coil 2D Cine MR Image Reconstructioncited by 7
  5. 2022A Projection-Based K-space Transformer Network for Undersampled Radial MRI Reconstruction with Limited Training Subjectscited by 4
  6. 2024Deep Separable Spatiotemporal Learning for Fast Dynamic Cardiac MRIcited by 4
  7. 2023HyperSLICE: HyperBand optimized Spiral for Low-latency Interactive Cardiac Examinationcited by 3
  8. 2022DDoS-UNet: Incorporating temporal information using Dynamic Dual-channel UNet for enhancing super-resolution of dynamic MRIcited by 1
  9. 2024Attention Incorporated Network for Sharing Low-rank, Image and K-space Information during MR Image Reconstruction to Achieve Single Breath-hold Cardiac Cine Imagingcited by 1
  10. 2025Deep Learning Assisted Outer Volume Removal for Highly-Accelerated Real-Time Dynamic MRIcited by 1
  11. 2022Artificial Intelligence-Based Image Reconstruction in Cardiac Magnetic Resonancecited by 0
  12. 2022Automated Diagnosis of Cardiovascular Diseases from Cardiac Magnetic Resonance Imaging Using Deep Learning Models: A Reviewcited by 0
2 more
  1. 2023The Challenge of Fetal Cardiac MRI Reconstruction Using Deep Learningcited by 0
  2. 2024Topology-Informed Machine Learning for Efficient Prediction of Solid Oxide Fuel Cell Electrode Polarizationcited by 0