In this study we assessed the repeatability of the values of radiomics features for small prostate tumors using test-retest Multiparametric Magnetic Resonance Imaging (mpMRI) images. The premise of radiomics is that quantitative image features can serve as biomarkers characterizing disease. For such biomarkers to be useful, repeatability is a basic requirement, meaning its value must remain stable between two scans, if the conditions remain stable. We investigated repeatability of radiomics features under various preprocessing and extraction configurations including various image normalization schemes, different image pre-filtering, 2D vs 3D texture computation, and different bin widths for image discretization. Image registration as means to re-identify regions of interest across time points was evaluated against human-expert segmented regions in both time points. Even though we found many radiomics features and preprocessing combinations with a high repeatability (Intraclass Correlation Coefficient (ICC) > 0.85), our results indicate that overall the repeatability is highly sensitive to the processing parameters (under certain configurations, it can be below 0.0). Image normalization, using a variety of approaches considered, did not result in consistent improvements in repeatability. There was also no consistent improvement of repeatability through the use of pre-filtering options, or by using image registration between timepoints to improve consistency of the region of interest localization. Based on these results we urge caution when interpreting radiomics features and advise paying close attention to the processing configuration details of reported results. Furthermore, we advocate reporting all processing details in radiomics studies and strongly recommend making the implementation available.
Key facts. Cited by 6 papers in the map (data through 7 Oct 2026). First posted on arXiv 16 Jul 2018.
Builds on
No reference list yet.
Built on by
Citing papers per year: 2022: 4; 2023: 1; 2024: 0; 2025: 1.
6 papers.
- 2022One Model to Synthesize Them All: Multi-contrast Multi-scale Transformer for Missing Data Imputationcited by 40
- 2022Improving the repeatability of deep learning models with Monte Carlo dropoutcited by 11
- 2022Open-radiomics: A Collection of Standardized Datasets and a Technical Protocol for Reproducible Radiomics Machine Learning Pipelinescited by 2
- 2023Feature Imitating Networks Enhance The Performance, Reliability And Speed Of Deep Learning On Biomedical Image Processing Taskscited by 2
- 2022Future Artificial Intelligence tools and perspectives in medicinecited by 0
- 2025X-ray transferable polyrepresentation learningcited by 0
- 2025X-ray transferable polyrepresentation learning7 Jul 2025
- 2023Feature Imitating Networks Enhance The Performance, Reliability And Speed Of Deep Learning On Biomedical Image Processing Tasks26 Jun 2023
- 2022Open-radiomics: A Collection of Standardized Datasets and a Technical Protocol for Reproducible Radiomics Machine Learning Pipelines29 Jul 2022
- 2022Future Artificial Intelligence tools and perspectives in medicine4 Jun 2022
- 2022One Model to Synthesize Them All: Multi-contrast Multi-scale Transformer for Missing Data Imputation28 Apr 2022
- 2022Improving the repeatability of deep learning models with Monte Carlo dropout15 Feb 2022