Learning to Assess Heartbeat Observability for mmWave Heart-Rate Sensing
Not on the map. Why?
Abstract (arXiv)
Contactless heart-rate sensing with millimeter-wave (mmWave) radar requires assessing whether individual measurements support reliable estimation. We study learning to assess heartbeat observability, defined as the readability of the heartbeat component in an acquired phase spectrum, for selective heart-rate estimation. Coherent superposition of scatterer returns can suppress this component even under similar macroscopic observation geometry, motivating assessment directly from acquired measurements. To obtain training supervision across different observability conditions, we develop a controllable multi-scatterer frequency-modulated continuous-wave (FMCW) simulator. Agreement between the dominant heartbeat-band peak and the known heart rate provides an automatic observability label for each simulated measurement. We propose HEAR (Heartbeat Estimation with Assessed Reliability), a compact dual-task Transformer that jointly predicts an observability score and heart rate. Its input combines spectral magnitudes with frequencies relative to the respiration fundamental, providing context for respiratory harmonics. Trained solely on simulated observations, HEAR transfers zero-shot to two public real-world datasets collected at 60 and 120 GHz from 134 subjects. The same learned score supports selective prediction with both HEAR's own heart-rate head and multiple existing estimators. On the 120 GHz dataset, score-based selection reduces the HR head's mean absolute error from 17.9 BPM at full coverage to 1.6 BPM at 50% coverage. The complete pipeline achieves an end-to-end processing latency of 50.8 ms on an edge device. Project page: https://yuxuanhu9.github.io/HEAR/.
Key facts. No citing papers in the map yet (data through 14 Oct 2026). Builds on 21 of its 66 references that are in the map. First posted on arXiv 2 Oct 2026.
Builds on
21 of 66 references.
References · 21
- 2017Attention Is All You Needcited by 60,361
- 2016Simple and Scalable Predictive Uncertainty Estimation using Deep Ensemblescited by 3,926
- 2016A Baseline for Detecting Misclassified and Out-of-Distribution Examples in Neural Networkscited by 2,385
- 2019AMASS: Archive of Motion Capture as Surface Shapescited by 1,236
- 2017Selective Classification for Deep Neural Networkscited by 852
- 2019Addressing Failure Prediction by Learning Model Confidencecited by 186
- 2018Bias-Reduced Uncertainty Estimation for Deep Neural Classifierscited by 113
- 2023Contrast-Phys+: Unsupervised and Weakly-supervised Video-based Remote Physiological Measurement via Spatiotemporal Contrastcited by 34
- 2022Facial Video-based Remote Physiological Measurement via Self-supervised Learningcited by 23
- 2024PhysMLE: Generalizable and Priors-Inclusive Multi-task Remote Physiological Measurementcited by 10
- 2021Contactless Electrocardiogram Monitoring with Millimeter Wave Radarcited by 9
- 2024radarODE: An ODE-Embedded Deep Learning Model for Contactless ECG Reconstruction from Millimeter-Wave Radarcited by 7
9 more
- 2025M4Human: A Large-Scale Multimodal mmWave Radar Benchmark for Human Mesh Reconstructioncited by 7
- 2025From High-SNR Radar Signal to ECG: A Transfer Learning Model with Cardio-Focusing Algorithm for Scenarios with Limited Datacited by 3
- 2026WaveMan: mmWave-Based Room-Scale Human Interaction Perception for Humanoid Robotscited by 3
- 2024Noncontact Multi-Point Vital Sign Monitoring with mmWave MIMO Radarcited by 2
- 2025Robust Phantom-Assisted Framework for Multi-Person Localization and Vital Signs Monitoring Using MIMO FMCW Radarcited by 1
- 2025Multidimensional Physiology-Inspired Enhanced Vital Sign Monitoring Using MIMO mmWave Bio-radarcited by 1
- 2026EM-Fall: Embodied mmWave Sensing for Day-and-Night Fall Detection on Humanoid Robotscited by 1
- 2026ActiveVital: Geometry-Aware Embodied Vital Signs Monitoring for Home Healthcare Robotscited by 1
- 2026mmHRI: Towards Privacy-Preserving Human-Robot Interaction with Millimeter-Wave Radarcited by 1
Built on by
Not cited yet.
Similar, not cited
Close in wording, no citation either way
- 2026mmWave-Diffusion:A Novel Framework for Respiration Sensing Using Observation-Anchored Conditional Diffusion Model
- 2026RPM-Distill: Physiology-guided Adaptive Cross-modal Distillation for Robust Remote Physiological Measurement
- 2023BeliefPPG: Uncertainty-aware Heart Rate Estimation from PPG signals via Belief Propagation
- 2025QualityFM: a Multimodal Physiological Signal Foundation Model with Self-Distillation for Signal Quality Challenges in Critically Ill Patients
- 2025Low-cost Embedded Breathing Rate Determination Using 802.15.4z IR-UWB Hardware for Remote Healthcare
- 2026A Two-Stage Motion-Aware Framework for mmWave-based Human Mesh Recovery
- 2026PhysAgent: A Multi-Agent Framework for Reliable Remote Heart Rate Estimation
- 2025Towards Characterizing Knowledge Distillation of PPG Heart Rate Estimation Models