mlsanityData to 7 Oct 2026

SCALE: Synthetic Calibration via Agreement Labeling in Embedding Space

arXiv 2609.38705 ↗First posted 30 Sep 2026cs.CVcited by 0

Not on the map. Why?

Abstract (arXiv)

Foundation models for computational pathology are usually evaluated using AUC and accuracy, while calibration is often left untested. This matters because a model can be accurate on average but still assign overly confident probabilities to cases that are difficult even for pathologists. We study calibration across eight pathology foundation models. Using pathologist agreement as a measure of diagnostic difficulty, we find that calibration error is consistently higher on low-agreement cases than on high-agreement cases. This pattern is not apparent from aggregate expected calibration error (ECE) alone. We then propose synthetic agreement calibration, a method for improving calibration without collecting multi-annotator labels. Given a trained linear probe, we select high-confidence embeddings as class anchors and interpolate between anchors from opposite classes. The interpolation weights encode a continuous notion of diagnostic ambiguity, which we use as a synthetic agreement signal to retrain the probe with agreement-aware label smoothing. On MHIST, which includes annotations from seven pathologists, synthetic agreement calibration recovers most of the calibration improvement obtained by label smoothing based on real pathologist agreement, while substantially reducing low-agreement ECE relative to the uncalibrated baseline. Discrimination metrics are preserved. On PatchCamelyon and BreakHis, public histopathology datasets without multi-annotator labels, the method improves calibration across the evaluated foundation models, whereas annotator-dependent approaches cannot be used without additional expert annotation.

Key facts. No citing papers in the map yet (data through 7 Oct 2026). Builds on 9 of its 20 references that are in the map. First posted on arXiv 30 Sep 2026.

Builds on

9 of 20 references.

References · 9

  1. 2015Deep Residual Learning for Image Recognitioncited by 51,809
  2. 2015Rethinking the Inception Architecture for Computer Visioncited by 5,451
  3. 2017On Calibration of Modern Neural Networkscited by 4,860
  4. 2019Can You Trust Your Model's Uncertainty? Evaluating Predictive Uncertainty Under Dataset Shiftcited by 1,274
  5. 2019When Does Label Smoothing Help?cited by 985
  6. 2018Rotation Equivariant CNNs for Digital Pathologycited by 420
  7. 2020Calibrating Deep Neural Networks using Focal Losscited by 353
  8. 2021A Petri Dish for Histopathology Image Analysiscited by 63
  9. 2022Calibrating Histopathology Image Classifiers using Label Smoothingcited by 3

Built on by

Not cited yet.