Personalising a Cross-User Surface Electromyography Encoder Under a Small Calibration Budget
Not on the map. Why?
Abstract (arXiv)
A myoelectric interface needs calibration from the user before it will function. Earlier work has treated calibration as a quantity, but has not asked the question of what a device should do with the calibration repetitions once they have been collected. This paper views personalizing the cross-user encoder as a design decision with a cost. Four alternative approaches to using exactly the same labeled repetitions were tested from a single cross-user encoder per held-out subject. Prototypical adaptation, linear probes, scaled fine-tuning and full fine-tuning were tested at every budget up to the maximum each database allows, five repetitions on DB1 and four on DB2 and DB5. Comparing four ways to spend a small calibration budget across 77 subjects, full fine-tuning is the most accurate at every budget, consistently enough that there is no exception among subsets of subjects. The result which impacts how one might make an engineering decision however is that a gradient free prototypical rule recovers 52 to 78 per cent of its benefit with no optimiser and no per-user copy of the weights, which makes personalisation something a worn device can do at donning time. The widespread intuition that a good representation only needs a fresh classifier is incorrect here. How well each method may perform relative to a per-user classifier that would be fitted by a clinic will depend on the specific database.
Key facts. No citing papers in the map yet (data through 14 Oct 2026). Builds on 8 of its 22 references that are in the map. First posted on arXiv 31 Jul 2026.
Builds on
8 of 22 references.
References · 8
- 2017Attention Is All You Needcited by 60,361
- 2017Prototypical Networks for Few-shot Learningcited by 3,015
- 2018Do Better ImageNet Models Transfer Better?cited by 565
- 2018Deep Learning for Electromyographic Hand Gesture Signal Classification Using Transfer Learningcited by 47
- 2019Domain Adaptation for sEMG-based Gesture Recognition with Recurrent Neural Networkscited by 15
- 2019Interpreting Deep Learning Features for Myoelectric Control: A Comparison with Handcrafted Featurescited by 11
- 2026A Montage-Agnostic Encoder for Calibration-Light Cross-User Gesture Recognition from Surface Electromyographycited by 2
- 2026Recognition and Label-Free Adaptation Across Recording Sessions in Surface-EMG Gesture Decodingcited by 2
Built on by
Not cited yet.
Similar, not cited
Close in wording, no citation either way
- 2026Lightweight Test-Time Adaptation for EMG-Based Gesture Recognition
- 2021Grasping force estimation using state-space model and Kalman filter ↗
- 2026Leveraging Convolutional Sparse Autoencoders for Robust Movement Classification from Low-Density sEMG
- 2026From Muscle Bursts to Motor Intent: Self-Supervised Token Modeling for Heterogeneous EMG
- 2025SASG-DA: Sparse-Aware Semantic-Guided Diffusion Augmentation For Myoelectric Gesture Recognition
- 2024SDEMG: Score-based Diffusion Model for Surface Electromyographic Signal Denoising
- 2025Motion Adaptation Across Users and Tasks for Exoskeletons via Meta-Learning ↗
- 2026MyoCodec: A Streaming Neural Codec for Electromyography