Multi-Channel Feature Fusion and Monte Carlo Dropout for Uncertainty-Aware Diabetic Retinopathy Grading
Not on the map. Why?
Abstract (arXiv)
Automated five-stage diabetic retinopathy (DR) grading requires more than high accuracy alone. Medical-grade deployment calls for lesion-aware preprocessing, ordinal predictions, calibrated uncertainty, and explainability to support reliable diagnostic systems. We present a unified pipeline that addresses these requirements using a Ben-Graham-green-channel CLAHE feature representation, an EfficientNetV2-L ordinal regressor, and Monte Carlo dropout for uncertainty-driven referral. Grad-CAM provides visual explanations aligned with clinically relevant lesions. The proposed method achieves a QWK of 91.31% on the APTOS-2019 official test split, placing it within the near-perfect agreement band (>80%). At a 20% referral rate, 293 of 366 images are automatically graded with a QWK of 90.40%. More complex cases are referred for specialist assessment, demonstrating a practical trade-off among grading quality, automation, and patient safety in robust, reliable, and deployment-ready medical diagnostic systems.
Key facts. No citing papers in the map yet (data through 14 Oct 2026). Builds on 6 of its 40 references that are in the map. First posted on arXiv 15 Aug 2026.
Builds on
6 of 40 references.
References · 6
- 2016Grad-CAM: Visual Explanations from Deep Networks via Gradient-based Localizationcited by 6,733
- 2015Dropout as a Bayesian Approximation: Representing Model Uncertainty in Deep Learningcited by 4,448
- 2021EfficientNetV2: Smaller Models and Faster Trainingcited by 1,135
- 2022Uncertainty-aware deep learning methods for robust diabetic retinopathy classificationcited by 8
- 2023Dual Branch Deep Learning Network for Detection and Stage Grading of Diabetic Retinopathycited by 7
- 2025Integrating Non-Linear Radon Transformation for Diabetic Retinopathy Gradingcited by 2
Built on by
Not cited yet.