mlsanityData to 14 Oct 2026

Towards an approach to multivariate outlier detection for District Heating System data

arXiv 2608.11375 ↗First posted 11 Aug 2026cs.LG cs.SY eess.SYcited by 0

Not on the map. Why?

Abstract (arXiv)

In this paper, we test different methods for multivariate detection of outliers in the data of transmitted heat energy in the selected substation of local District Heating System, by also considering outside ambient temperature, namely Z-score (univariate, as a benchmark), Mahalanobis distances, Principal Component Analysis (PCA), Isolation Forest and Hotelling's T-squared test. The overall research aims at uncovering irregular plant operation, with a wider objective of identifying the opportunities for reducing the consumption of gas in central heating plants as well as the CO2 emission. The proposed approach considers specific domain circumstances, such as irrelevance of zero transmit-ted energy timepoints as indication of off-grid plant. The outcomes of the different methods are discussed with domain experts. It was concluded that PCA, Isolation Forest and Hotelling method provide relevant results. Finally, we adopt the ensemble method (selection based on the agreement of all three methods on the detected outliers) as the final approach.

Key facts. No citing papers in the map yet (data through 14 Oct 2026). Builds on 2 of its 16 references that are in the map. First posted on arXiv 11 Aug 2026.

Builds on

2 of 16 references.

References · 2

  1. 2016LSTM-based Encoder-Decoder for Multi-sensor Anomaly Detectioncited by 215
  2. 2019MAD-GAN: Multivariate Anomaly Detection for Time Series Data with Generative Adversarial Networkscited by 176

Built on by

Not cited yet.