Overcoming the BCI Calibration Bottleneck: A Clinically-Grounded Architecture using Riemannian Alignment and Stochastic Weight Averaging
Not on the map. Why?
Abstract (arXiv)
Brain-Computer Interfaces (BCIs) face a severe calibration bottleneck due to cross-subject spatial covariance shifts and physiological artifacts. To enable zero-calibration BCI, a deep learning pipeline was engineered combining Per-Session Independent Component Analysis, Riemannian Euclidean Alignment, and EEGNet stabilized by Stochastic Weight Averaging (SWA). Evaluated on the strict MOABB BNCI2014-001 benchmark, the proposed architecture successfully isolates true sensorimotor rhythms. For the primary case study (Subject 1), a clinically robust SWA stable accuracy of 90.97% (AUC: 0.976, Cohen's kappa: 0.819) was achieved. Furthermore, expanded 9-fold Leave-One-Subject-Out (LOSO) cross-validation yielded a globally stable mean accuracy of 74.31%, proving hardware-agnostic zero-shot efficacy for binary motor imagery.
Key facts. No citing papers in the map yet (data through 14 Oct 2026). Builds on 4 of its 10 references that are in the map. First posted on arXiv 19 Jun 2026.
Builds on
4 of 10 references.
References · 4
- 2015Domain-Adversarial Training of Neural Networkscited by 3,044
- 2018Averaging Weights Leads to Wider Optima and Better Generalizationcited by 1,209
- 2016EEGNet: A Compact Convolutional Network for EEG-based Brain-Computer Interfacescited by 628
- 2018MOABB: Trustworthy algorithm benchmarking for BCIscited by 82
Built on by
Not cited yet.