Direct Time-of-Flight Measurement Accuracy Improvement With Perimeter-Gated SPADs
Not on the map. Why?
Abstract (arXiv)
Direct time of flight (dToF) measurements are susceptible to errors because of system-level and circuit-level timing jitters. In addition, device-level uncertainty stemming from the dark noise of single-photon avalanche diode (SPAD) contributes to the aggregated error. We demonstrate that perimeter gating can help reduce the device-level detection inaccuracy for SPAD devices by reducing the dark noise probability. Specifically, in this work, we developed a general framework to accurately estimate the dToF jitters stemming from different source levels and analyzed a counter-based time to digital converter (TDC) circuit that are commonly used in such systems. We have also measured dToFs using a perimeter-gated SPAD (pg-SPAD) detector fabricated in a 0.35 μm standard CMOS process. Experimental results show that pg-SPADs can improve measurement accuracy in both free-running and time-gated operations.
Key facts. No citing papers in the map yet (data through 14 Oct 2026). Builds on 1 of its 33 references that are in the map. First posted on arXiv 24 Jun 2026.
Builds on
1 of 33 references.
References · 1
Built on by
Not cited yet.