Patient-Level Elbow Abnormality Detection: Leakage-Aware Evaluation of Learned Preprocessing, Calibration, and Triage-Oriented Operating Points
Not on the map. Why?
Abstract (arXiv)
In this study, we examine learned preprocessing pipelines in the context of triage-oriented orthopedic abnormality detection task using elbow radiographs from MURA dataset. The evaluation focuses on patient-level detection of musculoskeletal abnormalities under a leakage-aware protocol. We compare multiple preprocessing pipelines, with and without a lightweight DnCNN module as a learned preprocessing component, to assess their impact on discrimination and calibration. Performance is assessed using discrimination metrics (AUROC, PR-AUC), calibration measures (ECE, Brier score), and validation-selected operating point analysis targeting high specificity. Results show that differences across preprocessing strategies are modest and configuration-dependent, with no consistent discrimination advantage over the raw-input DenseNet121 baseline. The raw and diverse inputs combined with the DnCNN front-end showed reduced ECE and Brier score, while CLAHE combined with DnCNN did not improve calibration. Overall, the results suggest that under patient-level evaluation, preprocessing gains are modest and configuration-dependent; the raw-input DenseNet121 baseline remains competitive throughout, and no tested preprocessing strategy produced a consistent discrimination advantage across all metrics.
Key facts. No citing papers in the map yet (data through 7 Oct 2026). Builds on 3 of its 17 references that are in the map. First posted on arXiv 30 Jun 2026.
Builds on
3 of 17 references.
References · 3
Built on by
Not cited yet.