Anatomy-Guided Residual Motion Diffusion for Controllable 4D Cardiac MRI Synthesis
Not on the map. Why?
Abstract (arXiv)
Developing robust artificial intelligence models for 4D (3D + time) medical imaging is constrained by limited annotated data, inter-device domain shifts, and privacy restrictions. To address this, we propose a 4D controllable generative framework for anatomically consistent data augmentation. A semi-supervised variational autoencoder learns a compact latent representation of anatomical volumes while jointly predicting aligned segmentation masks in a unified framework. Anatomical structure is then disentangled from temporal dynamics through a cascaded latent diffusion model (LDM). A static LDM generates subject-specific anatomy conditioned on clinical priors (diagnosis and volumes measures) and a subsequent motion LDM estimates residual latent motions, ensuring strict temporal coherence across the 4D sequence. The proposed approach was evaluated on cine cardiac MRI as a representative 4D imaging application. Experiments across multiple datasets demonstrate high controllability of static anatomy (Pearson r > 0.8) and strong temporal coherence (FVD = 288.08). In cross-vendor generalization experiments, augmenting training sets with synthetic 4D sequences significantly improves downstream segmentation performance. Using nnU-Net, the proposed augmentation strategy improves the average Dice score by 1.4% and reduces the Hausdorff Distance by 3.0mm compared to training on real data alone, for the left ventricle, Dice improves by 2.8% with a 5.4mm reduction in boundary error. Overall, this framework provides a scalable and controllable solution for 4D medical image synthesis, supporting the development of more robust models with limited annotations and cross-vendor variability. Code available on https://github.com/cyiheng/4DCardiacMRISynthesis.
Key facts. No citing papers in the map yet (data through 14 Oct 2026). Builds on 7 of its 18 references that are in the map. First posted on arXiv 25 Jun 2026.
Builds on
7 of 18 references.
References · 7
- 2021UNETR: Transformers for 3D Medical Image Segmentationcited by 959
- 2022Swin UNETR: Swin Transformers for Semantic Segmentation of Brain Tumors in MRI Imagescited by 830
- 2022Diffusion Models for Medical Image Analysis: A Comprehensive Surveycited by 273
- 2019Embracing Imperfect Datasets: A Review of Deep Learning Solutions for Medical Image Segmentationcited by 260
- 2024The Impact of Scanner Domain Shift on Deep Learning Performance in Medical Imaging: an Experimental Studycited by 16
- 2025Generative Artificial Intelligence in Medical Imaging: Foundations, Progress, and Clinical Translationcited by 8
- 2025Temporal Differential Fields for 4D Motion Modeling via Image-to-Video Synthesiscited by 3
Built on by
Not cited yet.
Similar, not cited
Close in wording, no citation either way
- 2026CardioDiT: Latent Diffusion Transformers for 4D Cardiac MRI Synthesis
- 2026Conditional Latent Diffusion Model with Fourier-based Motion Modelling for Virtual Population Synthesis
- 2022Diffusion Deformable Model for 4D Temporal Medical Image Generation
- 2026Temporally Consistent and Controllable Video Generation of 2D Cine CMR via Latent Space Motion Modeling
- 2026Piecewise Dynamic Diffusion Regularization for Reconstruction of Cardiac Cine MRI
- 2025CardioComposer: Leveraging Differentiable Geometry for Compositional Control of Anatomical Diffusion Models
- 2025Can Diffusion Models Bridge the Domain Gap in Cardiac MR Imaging?
- 2025Prior-Guided Residual Diffusion: Calibrated and Efficient Medical Image Segmentation