Cardiac Output Prediction from Echocardiograms: Self-Supervised Learning with Limited Data
Not on the map. Why?
Abstract (arXiv)
Cardiac Output (CO) is a key parameter in the diagnosis and management of cardiovascular diseases. However, its accurate measurement requires right-heart catheterization, an invasive and time-consuming procedure, motivating the development of reliable non-invasive alternatives using echocardiography. In this work, we propose a self-supervised learning (SSL) pretraining strategy based on SimCLR to improve CO prediction from apical four-chamber echocardiographic videos. The pretraining is performed using the same limited dataset available for the downstream task, demonstrating the potential of SSL even under data scarcity. Our results show that SSL mitigates overfitting and improves representation learning, achieving an average Pearson correlation of 0.41 on the test set and outperforming PanEcho, a model trained on over one million echocardiographic exams. Source code is available at https://github.com/EIDOSLAB/cardiac-output.
Key facts. No citing papers in the map yet (data through 7 Oct 2026). Builds on 4 of its 18 references that are in the map. First posted on arXiv 14 Feb 2026.
Builds on
4 of 18 references.
References · 4
- 2020A Simple Framework for Contrastive Learning of Visual Representationscited by 11,979
- 2021ViViT: A Video Vision Transformercited by 1,610
- 2022Contrastive learning for regression in multi-site brain age predictioncited by 14
- 2023A Review of Predictive and Contrastive Self-supervised Learning for Medical Imagescited by 10
Built on by
Not cited yet.