mlsanityData to 14 Oct 2026

Perfusion Imaging and Single Material Reconstruction in Polychromatic Photon Counting CT

arXiv 2602.02713 ↗First posted 2 Feb 2026physics.med-ph cs.CV eess.IVcited by 0

Not on the map. Why?

Abstract (arXiv)

Background: Perfusion computed tomography (CT) images the dynamics of a contrast agent through the body over time, and is one of the highest X-ray dose scans in medical imaging. Recently, a theoretically justified reconstruction algorithm based on a monotone variational inequality (VI) was proposed for single material polychromatic photon-counting CT, and showed promising early results at low-dose imaging. Purpose: We adapt this reconstruction algorithm for perfusion CT, to reconstruct the concentration map of the contrast agent while the static background tissue is assumed known; we call our method VI-PRISM (VI-based PeRfusion Imaging and Single Material reconstruction). We evaluate its potential for dose-reduced perfusion CT, using a digital phantom with water and iodine of varying concentration. Methods: Simulated iodine concentrations range from 0.05 to 2.5 mg/ml. The simulated X-ray source emits photons up to 100 keV, with average intensity ranging from 105 down to 102 photons per detector element. The number of tomographic projections was varied from 984 down to 8 to characterize the tradeoff in photon allocation between views and intensity. Results: We compare VI-PRISM against filtered back-projection (FBP), and find that VI-PRISM recovers iodine concentration with error below 0.4 mg/ml at all source intensity levels tested. Even with a dose reduction between 10x and 100x compared to FBP, VI-PRISM exhibits reconstruction quality on par with FBP. Conclusion: Across all photon budgets and angular sampling densities tested, VI-PRISM achieved consistently lower RMSE, reduced noise, and higher SNR compared to filtered back-projection. Even in extremely photon-limited and sparsely sampled regimes, VI-PRISM recovered iodine concentrations with errors below 0.4 mg/ml, showing that VI-PRISM can support accurate and dose-efficient perfusion imaging in photon-counting CT.

Key facts. No citing papers in the map yet (data through 14 Oct 2026). Builds on 4 of its 23 references that are in the map. First posted on arXiv 2 Feb 2026.

Builds on

4 of 23 references.

References · 4

  1. 2020Convergence for nonconvex ADMM, with applications to CT imagingcited by 8
  2. 2024TIGRE v3: Efficient and easy to use iterative computed tomographic reconstruction toolbox for real datasetscited by 5
  3. 2023Gradient Descent Provably Solves Nonlinear Tomographic Reconstructioncited by 3
  4. 2025Accurate, provable and fast polychromatic tomographic reconstruction: A variational inequality approachcited by 3

Built on by

Not cited yet.