Deadline-Aware, Energy-Efficient Control of Domestic Immersion Hot Water Heater
Not on the map. Why?
Abstract (arXiv)
Typical domestic immersion water heater systems are often operated continuously during winter, heating quickly rather than efficiently and ignoring predictable demand windows and ambient losses. We study deadline-aware control, where the aim is to reach a target temperature at a specified time while minimising energy consumption. We introduce an efficient Gymnasium environment that models an immersion hot water heater with first-order thermal losses and discrete on and off actions of 0 W and 6000 W applied every 120 seconds. Methods include a time-optimal bang-bang baseline, a zero-shot Monte Carlo Tree Search planner, and a Proximal Policy Optimisation policy. We report total energy consumption in watt-hours under identical physical dynamics. Across sweeps of initial temperature from 10 to 30 degrees Celsius, deadline from 30 to 90 steps, and target temperature from 40 to 80 degrees Celsius, PPO achieves the most energy-efficient performance at a 60-step horizon of 2 hours, using 3.23 kilowatt-hours, compared to 4.37 to 10.45 kilowatt-hours for bang-bang control and 4.18 to 6.46 kilowatt-hours for MCTS. This corresponds to energy savings of 26 percent at 30 steps and 69 percent at 90 steps. In a representative trajectory with a 50 kg water mass, 20 degrees Celsius ambient temperature, and a 60 degrees Celsius target, PPO consumes 54 percent less energy than bang-bang control and 33 percent less than MCTS. These results show that learned deadline-aware control reduces energy consumption under identical physical assumptions, while planners provide partial savings without training and learned policies offer near-zero inference cost once trained.
Key facts. No citing papers in the map yet (data through 14 Oct 2026). Builds on 3 of its 14 references that are in the map. First posted on arXiv 26 Jan 2026.
Builds on
3 of 14 references.
References · 3
- 2017Using Reinforcement Learning for Demand Response of Domestic Hot Water Buffers: a Real-Life Demonstrationcited by 3
- 2022Deep Reinforcement Learning for Heat Pump Controlcited by 3
- 2024Designing model predictive control strategies for grid-interactive water heaters for load shifting applicationscited by 1
Built on by
Not cited yet.
Similar, not cited
Close in wording, no citation either way
- 2026Scalable Supervisory HVAC Control for Linear Objectives ↗
- 2026Quantifying the Energy Floor: Direct Measurement and Replay Buffer Bias in SAC-Based HVAC Control on sbsim
- 2024The Smart Buildings Control Suite: A Diverse Open Source Benchmark to Evaluate and Scale HVAC Control Policies for Sustainability
- 2026ADAPT: Physics-Aware Diffusion-based World Models for Adaptive Predictive Transferable HVAC Control
- 2026Safe Deep Reinforcement Learning for Energy-Efficient HVAC Control in Multi-Zone Residential Buildings
- 2026Learning to Modulate, Not to Cycle: Soft Actor---Critic Recovers Inverter-Style Heat-Pump Control
- 2026Verifier-Based Reinforcement Fine-Tuning of Reasoning Models for Thermal Energy Storage Control
- 2026Reinforcement Learning-Based Co-Design and Operation of Chiller and Thermal Energy Storage for Cost-Optimal HVAC Systems