mlsanityData to 7 Oct 2026

Markerless Augmented Reality Registration for Surgical Guidance: A Multi-Anatomy Clinical Accuracy Study

arXiv 2511.02086 ↗First posted 3 Nov 2025cs.CVcited by 2

Not on the map. Why?

Abstract (arXiv)

Purpose: In this paper, we develop and clinically evaluate a depth-only, markerless augmented reality (AR) registration pipeline on a head-mounted display, and assess accuracy across small or low-curvature anatomies in real-life operative settings. Methods: On HoloLens 2, we align Articulated HAnd Tracking (AHAT) depth to Computed Tomography (CT)-derived skin meshes via (i) depth-bias correction, (ii) brief human-in-the-loop initialization, (iii) global and local registration. We validated the surface-tracing error metric by comparing "skin-to-bone" relative distances to CT ground truth on leg and foot models, using an AR-tracked tool. We then performed seven intraoperative target trials (feet x2, ear x3, leg x2) during the initial stage of fibula free-flap harvest and mandibular reconstruction surgery, and collected 500+ data per trial. Results: Preclinical validation showed tight agreement between AR-traced and CT distances (leg: median |Delta d| 0.78 mm, RMSE 0.97 mm; feet: 0.80 mm, 1.20 mm). Clinically, per-point error had a median of 3.9 mm. Median errors by anatomy were 3.2 mm (feet), 4.3 mm (ear), and 5.3 mm (lower leg), with 5 mm coverage 92-95%, 84-90%, and 72-86%, respectively. Feet vs. lower leg differed significantly (Delta median ~1.1 mm; p < 0.001). Conclusion: A depth-only, markerless AR pipeline on HMDs achieved ~3-4 mm median error across feet, ear, and lower leg in live surgical settings without fiducials, approaching typical clinical error thresholds for moderate-risk tasks. Human-guided initialization plus global-to-local registration enabled accurate alignment on small or low-curvature targets, improving the clinical readiness of markerless AR guidance.

Key facts. Cited by 2 papers in the map (data through 7 Oct 2026). Builds on 6 of its 27 references that are in the map. First posted on arXiv 3 Nov 2025.

Builds on

6 of 27 references.

References · 6

  1. 2022TotalSegmentator: robust segmentation of 104 anatomical structures in CT imagescited by 597
  2. 2020TEASER: Fast and Certifiable Point Cloud Registrationcited by 274
  3. 2022STTAR: Surgical Tool Tracking using off-the-shelf Augmented Reality Head-Mounted Displayscited by 17
  4. 2022Utility of Optical See-Through Head Mounted Displays in Augmented Reality-Assisted Surgery: A systematic reviewcited by 9
  5. 2023EVD Surgical Guidance with Retro-Reflective Tool Tracking and Spatial Reconstruction using Head-Mounted Augmented Reality Devicecited by 6
  6. 2025EasyREG: Easy Depth-Based Markerless Registration and Tracking using Augmented Reality Device for Surgical Guidancecited by 5

Built on by

Cited by year (2026 to 7 Oct)

Citing papers per year: 2026: 2.

2 papers.