mlsanityData to 14 Oct 2026

CLARAE: Clarity Preserving Reconstruction AutoEncoder for Denoising and Rhythm Classification of Intracardiac Electrograms

arXiv 2510.17821 ↗First posted 28 Sep 2025eess.SP cs.LGcited by 0

Not on the map. Why?

Abstract (arXiv)

Intracavitary atrial electrograms (EGMs) provide high-resolution insights into cardiac electrophysiology but are often contaminated by noise and remain high-dimensional, limiting real-time analysis. We introduce CLARAE (CLArity-preserving Reconstruction AutoEncoder), a one-dimensional encoder--decoder designed for atrial EGMs, which achieves both high-fidelity reconstruction and a compact 64-dimensional latent representation. CLARAE is designed to preserve waveform morphology, mitigate reconstruction artifacts, and produce interpretable embeddings through three principles: downsampling with pooling, a hybrid interpolation--convolution upsampling path, and a bounded latent space. We evaluated CLARAE on 495,731 EGM segments (unipolar and bipolar) from 29 patients across three rhythm types (AF, SR300, SR600). Performance was benchmarked against six state-of-the-art autoencoders using reconstruction metrics, rhythm classification, and robustness across signal-to-noise ratios from -5 to 15 dB. In downstream rhythm classification, CLARAE achieved F1-scores above 0.97 for all rhythm types, and its latent space showed clear clustering by rhythm. In denoising tasks, it consistently ranked among the top performers for both unipolar and bipolar signals. In order to promote reproducibility and enhance accessibility, we offer an interactive web-based application. This platform enables users to explore pre-trained CLARAE models, visualize the reconstructions, and compute metrics in real time. Overall, CLARAE combines robust denoising with compact, discriminative representations, offering a practical foundation for clinical workflows such as rhythm discrimination, signal quality assessment, and real-time mapping.

Key facts. No citing papers in the map yet (data through 14 Oct 2026). Builds on 4 of its 23 references that are in the map. First posted on arXiv 28 Sep 2025.

Builds on

4 of 23 references.

References · 4

  1. 2018Deep Recurrent Neural Networks for ECG Signal Denoisingcited by 14
  2. 2021DeepFilter: an ECG baseline wander removal filter using deep learning techniquescited by 11
  3. 2023Unsupervised Pre-Training Using Masked Autoencoders for ECG Analysiscited by 7
  4. 2025A Denoising VAE for Intracardiac Time Series in Ischemic Cardiomyopathycited by 1

Built on by

Not cited yet.