mlsanityData to 14 Oct 2026

Zero-shot self-supervised learning of single breath-hold magnetic resonance cholangiopancreatography (MRCP) reconstruction

arXiv 2508.09200 ↗First posted 8 Aug 2025eess.IV cs.AI cs.CVcited by 0

Not on the map. Why?

Abstract (arXiv)

To investigate the feasibility of zero-shot self-supervised learning reconstruction for reducing breath-hold times in magnetic resonance cholangiopancreatography (MRCP). Breath-hold MRCP was acquired from 11 healthy volunteers on 3T scanners using an incoherent k-space sampling pattern, leading to 14-second acquisition time and an acceleration factor of R=25. Zero-shot reconstruction was compared with parallel imaging of respiratory-triggered MRCP (338s, R=3) and compressed sensing reconstruction. For two volunteers, breath-hold scans (40s, R=6) were additionally acquired and retrospectively undersampled to R=25 to compute peak signal-to-noise ratio (PSNR). To address long zero-shot training time, the n+m full stages of the zero-shot learning were divided into two parts to reduce backpropagation depth during training: 1) n frozen stages initialized with n-stage pretrained network and 2) m trainable stages initialized either randomly or m-stage pretrained network. Efficiency of our approach was assessed by varying initialization strategies and the number of trainable stages using the retrospectively undersampled data. Zero-shot reconstruction significantly improved visual image quality over compressed sensing, particularly in SNR and ductal delineation, and achieved image quality comparable to that of successful respiratory-triggered acquisitions with regular breathing patterns. Improved initializations enhanced PSNR and reduced reconstruction time. Adjusting frozen/trainable configurations demonstrated that PSNR decreased only slightly from 38.25 dB (0/13) to 37.67 dB (12/1), while training time decreased up to 6.7-fold. Zero-shot learning delivers high-fidelity MRCP reconstructions with reduced breath-hold times, and the proposed partially trainable approach offers a practical solution for translation into time-constrained clinical workflows.

Key facts. No citing papers in the map yet (data through 14 Oct 2026). Builds on 10 of its 51 references that are in the map. First posted on arXiv 8 Aug 2025.

Builds on

10 of 51 references.

References · 10

  1. 2015Deep Residual Learning for Image Recognitioncited by 52,096
  2. 2016SGDR: Stochastic Gradient Descent with Warm Restartscited by 5,045
  3. 2020Implicit Neural Representations with Periodic Activation Functionscited by 2,238
  4. 2017Deep Image Priorcited by 1,098
  5. 2017MoDL: Model Based Deep Learning Architecture for Inverse Problemscited by 387
  6. 2021Zero-Shot Self-Supervised Learning for MRI Reconstructioncited by 54
  7. 2023IMJENSE: Scan-specific Implicit Representation for Joint Coil Sensitivity and Image Estimation in Parallel MRIcited by 23
  8. 2023Improved Multi-Shot Diffusion-Weighted MRI with Zero-Shot Self-Supervised Learning Reconstructioncited by 3
  9. 2021Robust partial Fourier reconstruction for diffusion-weighted imaging using a recurrent convolutional neural networkcited by 2
  10. 2024Deep Learning-based Accelerated MR Cholangiopancreatography without Fully-sampled Datacited by 2

Built on by

Not cited yet.