mlsanityData to 7 Oct 2026

Vibration-Based Energy Metric for Restoring Needle Alignment in Autonomous Robotic Ultrasound

arXiv 2508.06921 ↗First posted 9 Aug 2025cs.RO cs.CVcited by 0

Not on the map. Why?

Abstract (arXiv)

Precise needle alignment is essential for percutaneous needle insertion in robotic ultrasound-guided procedures. However, inherent challenges such as speckle noise, needle-like artifacts, and low image resolution make robust needle detection difficult, particularly when visibility is reduced or lost. In this paper, we propose a method to restore needle alignment when the ultrasound imaging plane and the needle insertion plane are misaligned. Unlike many existing approaches that rely heavily on needle visibility in ultrasound images, our method uses a more robust feature by periodically vibrating the needle using a mechanical system. Specifically, we propose a vibration-based energy metric that remains effective even when the needle is fully out of plane. Using this metric, we develop a control strategy to reposition the ultrasound probe in response to misalignments between the imaging plane and the needle insertion plane in both translation and rotation. Experiments conducted on ex-vivo porcine tissue samples using a dual-arm robotic ultrasound-guided needle insertion system demonstrate the effectiveness of the proposed approach. The experimental results show the translational error of 0.41±0.27 mm and the rotational error of 0.51±0.19 degrees.

Key facts. No citing papers in the map yet (data through 7 Oct 2026). Builds on 9 of its 30 references that are in the map. First posted on arXiv 9 Aug 2025.

Builds on

9 of 30 references.

References · 9

  1. 2020An Image is Worth 16x16 Words: Transformers for Image Recognition at Scalecited by 29,915
  2. 2023Robotic Ultrasound Imaging: State-of-the-Art and Future Perspectivescited by 29
  3. 2016Towards MRI-Based Autonomous Robotic US Acquisitions: A First Feasibility Studycited by 28
  4. 2024Machine Learning in Robotic Ultrasound Imaging: Challenges and Perspectivescited by 17
  5. 2023Intelligent Robotic Sonographer: Mutual Information-based Disentangled Reward Learning from Few Demonstrationscited by 14
  6. 2022Towards Autonomous Atlas-based Ultrasound Acquisitions in Presence of Articulated Motioncited by 12
  7. 2023Motion Magnification in Robotic Sonography: Enabling Pulsation-Aware Artery Segmentationcited by 9
  8. 2024VibNet: Vibration-Boosted Needle Detection in Ultrasound Imagescited by 5
  9. 2024Needle Segmentation Using GAN: Restoring Thin Instrument Visibility in Robotic Ultrasoundcited by 3

Built on by

Not cited yet.