Objective Task-based Evaluation of Quantitative Medical Imaging Methods: Emerging Frameworks and Future Directions
Not on the map. Why?
Abstract (arXiv)
Quantitative imaging (QI) is demonstrating strong promise across multiple clinical applications. For clinical translation of QI methods, objective evaluation on clinically relevant tasks is essential. To address this need, multiple evaluation strategies are being developed. In this paper, based on previous literature, we outline four emerging frameworks to perform evaluation studies of QI methods. We first discuss the use of virtual imaging trials (VITs) to evaluate QI methods. Next, we outline a no-gold-standard evaluation framework to clinically evaluate QI methods without ground truth. Third, a framework to evaluate QI methods for joint detection and quantification tasks is outlined. Finally, we outline a framework to evaluate QI methods that output multi-dimensional parameters, such as radiomic features. We review these frameworks, discussing their utilities and limitations. Further, we examine future research areas in evaluation of QI methods. Given the recent advancements in PET, including long axial field-of-view scanners and the development of artificial-intelligence algorithms, we present these frameworks in the context of PET.
Key facts. No citing papers in the map yet (data through 7 Oct 2026). Builds on 6 of its 88 references that are in the map. First posted on arXiv 7 Jul 2025.
Builds on
6 of 88 references.
References · 6
- 2021Objective task-based evaluation of artificial intelligence-based medical imaging methods: Framework, strategies and role of the physiciancited by 15
- 2020A Physics-Guided Modular Deep-Learning Based Automated Framework for Tumor Segmentation in PET Imagescited by 6
- 2021A Hybrid Approach for Approximating the Ideal Observer for Joint Signal Detection and Estimation Tasks by Use of Supervised Learning and Markov-Chain Monte Carlo Methodscited by 5
- 2020A Bayesian approach to tissue-fraction estimation for oncological PET segmentationcited by 3
- 2022No-gold-standard evaluation of quantitative imaging methods in the presence of correlated noisecited by 1
- 2023Observer study-based evaluation of TGAN architecture used to generate oncological PET imagescited by 1
Built on by
Not cited yet.