mlsanityData to 14 Oct 2026

Examining Deployment and Refinement of the VIOLA-AI Intracranial Hemorrhage Model Using an Interactive NeoMedSys Platform

arXiv 2505.09380 ↗First posted 14 May 2025cs.CV cs.AI cs.LGcited by 1

Not on the map. Why?

Abstract (arXiv)

Background: There are many challenges and opportunities in the clinical deployment of AI tools in radiology. The current study describes a radiology software platform called NeoMedSys that can enable efficient deployment and refinements of AI models. We evaluated the feasibility and effectiveness of running NeoMedSys for three months in real-world clinical settings and focused on improvement performance of an in-house developed AI model (VIOLA-AI) designed for intracranial hemorrhage (ICH) detection. Methods: NeoMedSys integrates tools for deploying, testing, and optimizing AI models with a web-based medical image viewer, annotation system, and hospital-wide radiology information systems. A prospective pragmatic investigation was deployed using clinical cases of patients presenting to the largest Emergency Department in Norway (site-1) with suspected traumatic brain injury (TBI) or patients with suspected stroke (site-2). We assessed ICH classification performance as VIOLA-AI encountered new data and underwent pre-planned model retraining. Performance metrics included sensitivity, specificity, accuracy, and the area under the receiver operating characteristic curve (AUC). Results: NeoMedSys facilitated iterative improvements in the AI model, significantly enhancing its diagnostic accuracy. Automated bleed detection and segmentation were reviewed in near real-time to facilitate re-training VIOLA-AI. The iterative refinement process yielded a marked improvement in classification sensitivity, rising to 90.3% (from 79.2%), and specificity that reached 89.3% (from 80.7%). The bleed detection ROC analysis for the entire sample demonstrated a high area-under-the-curve (AUC) of 0.949 (from 0.873). Model refinement stages were associated with notable gains, highlighting the value of real-time radiologist feedback.

Key facts. Cited by 1 paper in the map (data through 14 Oct 2026). Builds on 4 of its 29 references that are in the map. First posted on arXiv 14 May 2025.

Builds on

4 of 29 references.

References · 4

  1. 2023BHSD: A 3D Multi-Class Brain Hemorrhage Segmentation Datasetcited by 27
  2. 2023The state-of-the-art 3D anisotropic intracranial hemorrhage segmentation on non-contrast head CT: The INSTANCE challengecited by 26
  3. 2019Integrating AI into Radiology workflow: Levels of research, production, and feedback maturitycited by 7
  4. 2022Voxels Intersecting along Orthogonal Levels Attention U-Net for Intracerebral Haemorrhage Segmentation in Head CTcited by 4

Built on by

Cited by year (2026 to 14 Oct)

Citing papers per year: 2026: 1.

1 paper.