mlsanityData to 14 Oct 2026

Retinal arterial blood flow measured by real-time Doppler holography at 33,000 frames per second

arXiv 2409.17180 ↗First posted 24 Sep 2024eess.IV physics.app-ph physics.ins-detcited by 1

Not on the map. Why?

Abstract (arXiv)

This study presents a novel quantitative estimation method for total retinal arterial blood flow utilizing real-time Doppler holography at an unprecedented frame rate of 33,000 frames per second. This technique, leveraging high-speed digital holography, enables non-invasive angiographic imaging of the retina, providing detailed blood flow contrasts essential for assessing retinal health. The proposed quantitative analysis method consists of segmenting primary in-plane retinal arteries and calculating local blood velocity using Doppler frequency broadening. The analysis integrates a forward scattering model to achieve blood flow estimation. Our findings highlight the potential of Doppler holography as a powerful tool for diagnosing and monitoring the treatment of retinal vascular conditions, complementary to existing imaging methods.

Key facts. Cited by 1 paper in the map (data through 14 Oct 2026). First posted on arXiv 24 Sep 2024.

Builds on

No reference list yet.

Built on by

Cited by year

Citing papers per year: 2025: 1.

1 paper.