Sequential-Scanning Dual-Energy CT Imaging Using High Temporal Resolution Image Reconstruction and Error-Compensated Material Basis Image Generation
Not on the map. Why?
Abstract (arXiv)
Dual-energy computed tomography (DECT) has been widely used to obtain quantitative elemental composition of imaged subjects for personalized and precise medical diagnosis. Compared with DECT leveraging advanced X-ray source and/or detector technologies, the use of the sequential-scanning data acquisition scheme to implement DECT may make a broader impact on clinical practice because this scheme requires no specialized hardware designs and can be directly implemented into conventional CT systems. However, since the concentration of iodinated contrast agent in the imaged subject varies over time, sequentially scanned data sets acquired at two tube potentials are temporally inconsistent. As existing material basis image reconstruction approaches assume that the data sets acquired at two tube potentials are temporally consistent, the violation of this assumption results in inaccurate quantification of material concentration. In this work, we developed sequential-scanning DECT imaging using high temporal resolution image reconstruction and error-compensated material basis image generation, ACCELERATION in short, to address the technical challenge induced by temporal inconsistency of sequentially scanned data sets and improve quantification accuracy of material concentration in sequential-scanning DECT. ACCELERATION has been validated and evaluated using numerical simulation data sets generated from clinical human subject exams and experimental human subject studies. Results demonstrated the improvement of quantification accuracy and image quality using ACCELERATION.
Key facts. No citing papers in the map yet (data through 7 Oct 2026). Builds on 7 of its 29 references that are in the map. First posted on arXiv 27 Aug 2024.
Builds on
7 of 29 references.
References · 7
- 2020Implicit Neural Representations with Periodic Activation Functionscited by 2,214
- 2017Deep Image Priorcited by 1,097
- 2021NeRP: Implicit Neural Representation Learning with Prior Embedding for Sparsely Sampled Image Reconstructioncited by 145
- 2023Implicit Neural Representation in Medical Imaging: A Comparative Surveycited by 88
- 2021Dynamic CT Reconstruction from Limited Views with Implicit Neural Representations and Parametric Motion Fieldscited by 69
- 2021An Educated Warm Start For Deep Image Prior-Based Micro CT Reconstructioncited by 16
- 2023Differentiable Forward Projector for X-ray Computed Tomographycited by 14
Built on by
Not cited yet.