MBSS-T1: Model-Based Subject-Specific Self-Supervised Motion Correction for Robust Cardiac T1 Mapping
Not on the map. Why?
Abstract (arXiv)
Cardiac T1 mapping is a valuable quantitative MRI technique for diagnosing diffuse myocardial diseases. Traditional methods, relying on breath-hold sequences and cardiac triggering based on an ECG signal, face challenges with patient compliance, limiting their effectiveness. Image registration can enable motion-robust cardiac T1 mapping, but inherent intensity differences between time points pose a challenge. We present MBSS-T1, a subject-specific self-supervised model for motion correction in cardiac T1 mapping. Physical constraints, implemented through a loss function comparing synthesized and motion-corrected images, enforce signal decay behavior, while anatomical constraints, applied via a Dice loss, ensure realistic deformations. The unique combination of these constraints results in motion-robust cardiac T1 mapping along the longitudinal relaxation axis. In a 5-fold experiment on a public dataset of 210 patients (STONE sequence) and an internal dataset of 19 patients (MOLLI sequence), MBSS-T1 outperformed baseline deep-learning registration methods. It achieved superior model fitting quality (R2: 0.975 vs. 0.941, 0.946 for STONE; 0.987 vs. 0.982, 0.965 for MOLLI free-breathing; 0.994 vs. 0.993, 0.991 for MOLLI breath-hold), anatomical alignment (Dice: 0.89 vs. 0.84, 0.88 for STONE; 0.963 vs. 0.919, 0.851 for MOLLI free-breathing; 0.954 vs. 0.924, 0.871 for MOLLI breath-hold), and visual quality (4.33 vs. 3.38, 3.66 for STONE; 4.1 vs. 3.5, 3.28 for MOLLI free-breathing; 3.79 vs. 3.15, 2.84 for MOLLI breath-hold). MBSS-T1 enables motion-robust T1 mapping for broader patient populations, overcoming challenges such as suboptimal compliance, and facilitates free-breathing cardiac T1 mapping without requiring large annotated datasets. Our code is available at https://github.com/TechnionComputationalMRILab/MBSS-T1.
Key facts. Cited by 2 papers in the map (data through 14 Oct 2026). Builds on 10 of its 40 references that are in the map. First posted on arXiv 21 Aug 2024.
Builds on
10 of 40 references.
References · 10
- 2020RAFT: Recurrent All-Pairs Field Transforms for Optical Flowcited by 2,415
- 2018VoxelMorph: A Learning Framework for Deformable Medical Image Registrationcited by 662
- 2019Unsupervised Learning of Probabilistic Diffeomorphic Registration for Images and Surfacescited by 186
- 2020SynthMorph: learning contrast-invariant registration without acquired imagescited by 140
- 2018Joint Learning of Motion Estimation and Segmentation for Cardiac MR Image Sequencescited by 47
- 2024Memorization in deep learning: A surveycited by 15
- 2021LAPNet: Non-rigid Registration derived in k-space for Magnetic Resonance Imagingcited by 11
- 2018Enhancing Label-Driven Deep Deformable Image Registration with Local Distance Metrics for State-of-the-Art Cardiac Motion Trackingcited by 7
- 2023PCMC-T1: Free-breathing myocardial T1 mapping with Physically-Constrained Motion Correctioncited by 6
- 2021Deep-Learning based Motion Correction for Myocardial T1 Mappingcited by 4
Built on by
Citing papers per year: 2025: 1; 2026: 1.
2 papers.