mlsanityData to 7 Oct 2026

Regional quality estimation for echocardiography using deep learning

arXiv 2408.00591 ↗First posted 1 Aug 2024eess.IV cs.CVcited by 0

Not on the map. Why?

Abstract (arXiv)

Automatic estimation of cardiac ultrasound image quality can be beneficial for guiding operators and ensuring the accuracy of clinical measurements. Previous work often fails to distinguish the view correctness of the echocardiogram from the image quality. Additionally, previous studies only provide a global image quality value, which limits their practical utility. In this work, we developed and compared three methods to estimate image quality: 1) classic pixel-based metrics like the generalized contrast-to-noise ratio (gCNR) on myocardial segments as region of interest and left ventricle lumen as background, obtained using a U-Net segmentation 2) local image coherence derived from a U-Net model that predicts coherence from B-Mode images 3) a deep convolutional network that predicts the quality of each region directly in an end-to-end fashion. We evaluate each method against manual regional image quality annotations by three experienced cardiologists. The results indicate poor performance of the gCNR metric, with Spearman correlation to the annotations of rho = 0.24. The end-to-end learning model obtains the best result, rho = 0.69, comparable to the inter-observer correlation, rho = 0.63. Finally, the coherence-based method, with rho = 0.58, outperformed the classical metrics and is more generic than the end-to-end approach. The image quality prediction tool is available as an open source Python library at https://github.com/GillesVanDeVyver/arqee.

Key facts. No citing papers in the map yet (data through 7 Oct 2026). Builds on 8 of its 41 references that are in the map. First posted on arXiv 1 Aug 2024.

Builds on

8 of 41 references.

References · 8

  1. 2019EfficientNet: Rethinking Model Scaling for Convolutional Neural Networkscited by 6,415
  2. 2018MobileNetV2: Inverted Residuals and Linear Bottleneckscited by 4,773
  3. 2016Gaussian Error Linear Units (GELUs)cited by 3,431
  4. 2019Deep Learning for Segmentation using an Open Large-Scale Dataset in 2D Echocardiographycited by 243
  5. 2016Squared Earth Mover's Distance-based Loss for Training Deep Neural Networkscited by 45
  6. 2020Automatic Probe Movement Guidance for Freehand Obstetric Ultrasoundcited by 27
  7. 2018Classifying a specific image region using convolutional nets with an ROI mask as inputcited by 4
  8. 2022Automated Assessment of Transthoracic Echocardiogram Image Quality Using Deep Neural Networkscited by 1

Built on by

Not cited yet.