A Domain Adaptation Model for Carotid Ultrasound: Image Harmonization, Noise Reduction, and Impact on Cardiovascular Risk Markers
Not on the map. Why?
Abstract (arXiv)
Deep learning has been used extensively for medical image analysis applications, assuming the training and test data adhere to the same probability distributions. However, a common challenge arises when dealing with medical images generated by different systems or even the same system with varying parameter settings. Such images often contain diverse textures and noise patterns, violating the assumption. Consequently, models trained on data from one machine or setting usually struggle to perform effectively on data from another. To address this issue in ultrasound images, we proposed a Generative Adversarial Network (GAN) based model in this paper. We formulated image harmonization and denoising tasks as an image-to-image translation task, wherein we modified the texture pattern and reduced noise in Carotid ultrasound images while keeping the image content (the anatomy) unchanged. The performance was evaluated using feature distribution and pixel-space similarity metrics. In addition, blood-to-tissue contrast and influence on computed risk markers (Gray scale median, GSM) were evaluated. The results showed that domain adaptation was achieved in both tasks (histogram correlation 0.920 and 0.844), as compared to no adaptation (0.890 and 0.707), and that the anatomy of the images was retained (structure similarity index measure of the arterial wall 0.71 and 0.80). In addition, the image noise level (contrast) did not change in the image harmonization task (-34.1 vs 35.2 dB) but was improved in the noise reduction task (-23.5 vs -46.7 dB). The model outperformed the CycleGAN in both tasks. Finally, the risk marker GSM increased by 7.6 (p<0.001) in task 1 but not in task 2. We conclude that domain translation models are powerful tools for ultrasound image improvement while retaining the underlying anatomy but that downstream calculations of risk markers may be affected.
Key facts. Cited by 3 papers in the map (data through 14 Oct 2026). Builds on 8 of its 48 references that are in the map. First posted on arXiv 6 Jul 2024.
Builds on
8 of 48 references.
References · 8
- 2017A Survey on Deep Learning in Medical Image Analysiscited by 1,186
- 2016Deep Transfer Learning with Joint Adaptation Networkscited by 612
- 2019Deep Learning for Image Super-resolution: A Surveycited by 369
- 2021Domain Adaptation for Medical Image Analysis: A Surveycited by 352
- 2017Demystifying Neural Style Transfercited by 152
- 2018Translating and Segmenting Multimodal Medical Volumes with Cycle- and Shape-Consistency Generative Adversarial Networkcited by 97
- 2022R2U++: A Multiscale Recurrent Residual U-Net with Dense Skip Connections for Medical Image Segmentationcited by 11
- 2021Ultrasound Domain Adaptation Using Frequency Domain Analysiscited by 4
Built on by
Citing papers per year: 2024: 1; 2025: 0; 2026: 2.
3 papers.
- 2026Domain Adaptation of Carotid Ultrasound Images using Generative Adversarial Networkcited by 1
- 2024Emulating Clinical Quality Muscle B-mode Ultrasound Images from Plane Wave Images Using a Two-Stage Machine Learning Modelcited by 0
- 2026Fine-Tuning Cycle-GAN for Domain Adaptation of MRI Imagescited by 0
- 2026Fine-Tuning Cycle-GAN for Domain Adaptation of MRI Images18 Jan 2026
- 2026Domain Adaptation of Carotid Ultrasound Images using Generative Adversarial Network4 Jan 2026
- 2024Emulating Clinical Quality Muscle B-mode Ultrasound Images from Plane Wave Images Using a Two-Stage Machine Learning Model7 Dec 2024