Bayesian Windkessel calibration using optimized 0D surrogate models
Not on the map. Why?
Abstract (arXiv)
Boundary condition (BC) calibration to assimilate clinical measurements is an essential step in any subject-specific simulation of cardiovascular fluid dynamics. Bayesian calibration approaches have successfully quantified the uncertainties inherent in identified parameters. Yet, routinely estimating the posterior distribution for all BC parameters in 3D simulations has been unattainable due to the infeasible computational demand. We propose an efficient method to identify Windkessel parameter posteriors using results from a single high-fidelity three-dimensional (3D) model evaluation. We only evaluate the 3D model once for an initial choice of BCs and use the result to create a highly accurate zero-dimensional (0D) surrogate. We then perform Sequential Monte Carlo (SMC) using the optimized 0D model to derive the high-dimensional Windkessel BC posterior distribution. We validate this approach in a publicly available dataset of N=72 subject-specific vascular models. We found that optimizing 0D models to match 3D data a priori lowered their median approximation error by nearly one order of magnitude. In a subset of models, we confirm that the optimized 0D models still generalize to a wide range of BCs. Finally, we present the high-dimensional Windkessel parameter posterior for different measured signal-to-noise ratios in a vascular model using SMC. We further validate that the 0D-derived posterior is a good approximation of the 3D posterior. The minimal computational demand of our method using a single 3D simulation, combined with the open-source nature of all software and data used in this work, will increase access and efficiency of Bayesian Windkessel calibration in cardiovascular fluid dynamics simulations.
Key facts. Cited by 3 papers in the map (data through 14 Oct 2026). First posted on arXiv 22 Apr 2024.
Builds on
No reference list yet.
Built on by
Citing papers per year: 2024: 1; 2025: 1; 2026: 1.
3 papers.
- 2024FUSE: Fast Unified Simulation and Estimation for PDEscited by 8
- 2025On the performance of multi-fidelity and reduced-dimensional neural emulators for inference of physiological boundary conditionscited by 1
- 2026FalconBC: Flow matching for Amortized inference of Latent-CONditioned physiologic Boundary Conditionscited by 1
- 2026FalconBC: Flow matching for Amortized inference of Latent-CONditioned physiologic Boundary Conditions18 Mar 2026
- 2025On the performance of multi-fidelity and reduced-dimensional neural emulators for inference of physiological boundary conditions13 Jun 2025
- 2024FUSE: Fast Unified Simulation and Estimation for PDEs23 May 2024