mlsanityData to 7 Oct 2026

An end-to-end deep learning pipeline to derive blood input with partial volume corrections for automated parametric brain PET mapping

arXiv 2402.03414 ↗First posted 5 Feb 2024eess.IV cs.CV cs.LGcited by 0

Not on the map. Why?

Abstract (arXiv)

Dynamic 2-[18F] fluoro-2-deoxy-D-glucose positron emission tomography (dFDG-PET) for human brain imaging has considerable clinical potential, yet its utilization remains limited. A key challenge in the quantitative analysis of dFDG-PET is characterizing a patient-specific blood input function, traditionally reliant on invasive arterial blood sampling. This research introduces a novel approach employing non-invasive deep learning model-based computations from the internal carotid arteries (ICA) with partial volume (PV) corrections, thereby eliminating the need for invasive arterial sampling. We present an end-to-end pipeline incorporating a 3D U-Net based ICA-net for ICA segmentation, alongside a Recurrent Neural Network (RNN) based MCIF-net for the derivation of a model-corrected blood input function (MCIF) with PV corrections. The developed 3D U-Net and RNN was trained and validated using a 5-fold cross-validation approach on 50 human brain FDG PET datasets. The ICA-net achieved an average Dice score of 82.18% and an Intersection over Union of 68.54% across all tested scans. Furthermore, the MCIF-net exhibited a minimal root mean squared error of 0.0052. The application of this pipeline to ground truth data for dFDG-PET brain scans resulted in the precise localization of seizure onset regions, which contributed to a successful clinical outcome, with the patient achieving a seizure-free state after treatment. These results underscore the efficacy of the ICA-net and MCIF-net deep learning pipeline in learning the ICA structure's distribution and automating MCIF computation with PV corrections. This advancement marks a significant leap in non-invasive neuroimaging.

Key facts. No citing papers in the map yet (data through 7 Oct 2026). Builds on 5 of its 55 references that are in the map. First posted on arXiv 5 Feb 2024.

Builds on

5 of 55 references.

References · 5

  1. 20163D U-Net: Learning Dense Volumetric Segmentation from Sparse Annotationcited by 1,471
  2. 2014On the Properties of Neural Machine Translation: Encoder-Decoder Approachescited by 1,303
  3. 2021UNETR: Transformers for 3D Medical Image Segmentationcited by 954
  4. 2021Medical Transformer: Gated Axial-Attention for Medical Image Segmentationcited by 319
  5. 2022Transformers in Time-series Analysis: A Tutorialcited by 45

Built on by

Not cited yet.