Evaluation of an automated choroid segmentation algorithm in a longitudinal kidney donor and recipient cohort
Not on the map. Why?
Abstract (arXiv)
Purpose: To evaluate the performance of an automated choroid segmentation algorithm in optical coherence tomography (OCT) data using a longitudinal kidney donor and recipient cohort. Methods: We assessed 22 donors and 23 patients requiring renal transplantation over up to 1 year post-transplant. We measured choroidal thickness (CT) and area and compared our automated CT measurements to manual ones at the same locations. We estimated associations between choroidal measurements and markers of renal function (estimated glomerular filtration rate (eGFR), serum creatinine and urea) using correlation and linear mixed-effects (LME) modelling. Results: There was good agreement between manual and automated CT. Automated measures were more precise because of smaller measurement error over time. External adjudication of major discrepancies were in favour of automated measures. Significant differences were observed in the choroid pre- and post-transplant in both cohorts, and LME modelling revealed significant linear associations observed between choroidal measures and renal function in recipients. Significant associations were mostly stronger with automated CT (eGFR P<0.001, creatinine P=0.004, urea P=0.04) compared to manual CT (eGFR P=0.002, creatinine P=0.01, urea P=0.03). Conclusions: Our automated approach has greater precision than human-performed manual measurements, which may explain stronger associations with renal function compared to manual measurements. To improve detection of meaningful associations with clinical endpoints in longitudinal studies of OCT, reducing measurement error should be a priority, and automated measurements help achieve this. Translational relevance: We introduce a novel choroid segmentation algorithm which can replace manual grading for studying the choroid in renal disease, and other clinical conditions.
Key facts. Cited by 3 papers in the map (data through 14 Oct 2026). First posted on arXiv 19 Jun 2023.
Builds on
No reference list yet.
Built on by
Citing papers per year: 2023: 2; 2024: 1.
3 papers.
- 2023An open-source deep learning algorithm for efficient and fully-automatic analysis of the choroid in optical coherence tomographycited by 4
- 2023Choroidalyzer: An open-source, end-to-end pipeline for choroidal analysis in optical coherence tomographycited by 4
- 2024Domain-specific augmentations with resolution agnostic self-attention mechanism improves choroid segmentation in optical coherence tomography imagescited by 0
- 2024Domain-specific augmentations with resolution agnostic self-attention mechanism improves choroid segmentation in optical coherence tomography images23 May 2024
- 2023Choroidalyzer: An open-source, end-to-end pipeline for choroidal analysis in optical coherence tomography5 Dec 2023
- 2023An open-source deep learning algorithm for efficient and fully-automatic analysis of the choroid in optical coherence tomography3 Jul 2023