mlsanityData to 7 Oct 2026

"Can't Take the Pressure?": Examining the Challenges of Blood Pressure Estimation via Pulse Wave Analysis

arXiv 2304.14916 ↗First posted 23 Apr 2023eess.SP cs.AI cs.HCcited by 2

Not on the map. Why?

Abstract (arXiv)

The use of observed wearable sensor data (e.g., photoplethysmograms [PPG]) to infer health measures (e.g., glucose level or blood pressure) is a very active area of research. Such technology can have a significant impact on health screening, chronic disease management and remote monitoring. A common approach is to collect sensor data and corresponding labels from a clinical grade device (e.g., blood pressure cuff), and train deep learning models to map one to the other. Although well intentioned, this approach often ignores a principled analysis of whether the input sensor data has enough information to predict the desired metric. We analyze the task of predicting blood pressure from PPG pulse wave analysis. Our review of the prior work reveals that many papers fall prey data leakage, and unrealistic constraints on the task and the preprocessing steps. We propose a set of tools to help determine if the input signal in question (e.g., PPG) is indeed a good predictor of the desired label (e.g., blood pressure). Using our proposed tools, we have found that blood pressure prediction using PPG has a high multi-valued mapping factor of 33.2% and low mutual information of 9.8%. In comparison, heart rate prediction using PPG, a well-established task, has a very low multi-valued mapping factor of 0.75% and high mutual information of 87.7%. We argue that these results provide a more realistic representation of the current progress towards to goal of wearable blood pressure measurement via PPG pulse wave analysis.

Key facts. Cited by 2 papers in the map (data through 7 Oct 2026). Builds on 9 of its 68 references that are in the map. First posted on arXiv 23 Apr 2023.

Builds on

9 of 68 references.

References · 9

  1. 2015Deep Residual Learning for Image Recognitioncited by 51,809
  2. 2016Densely Connected Convolutional Networkscited by 6,691
  3. 2020Multi-Task Temporal Shift Attention Networks for On-Device Contactless Vitals Measurementcited by 133
  4. 2020PPG2ABP: Translating Photoplethysmogram (PPG) Signals to Arterial Blood Pressure (ABP) Waveforms using Fully Convolutional Neural Networkscited by 18
  5. 2021A Deep Learning Approach to Predict Blood Pressure from PPG Signalscited by 6
  6. 2021A Shallow U-Net Architecture for Reliably Predicting Blood Pressure (BP) from Photoplethysmogram (PPG) and Electrocardiogram (ECG) Signalscited by 4
  7. 2022MobilePhys: Personalized Mobile Camera-Based Contactless Physiological Sensingcited by 4
  8. 2021SmartKC: Smartphone-based Corneal Topographer for Keratoconus Detectioncited by 3
  9. 2022Towards Automating Retinoscopy for Refractive Error Diagnosiscited by 1

Built on by

Cited by year

Citing papers per year: 2023: 1; 2024: 0; 2025: 1.

2 papers.