Adapting Datacenter Capacity for Greener Datacenters and Grid
Not on the map. Why?
Abstract (arXiv)
Cloud providers are adapting datacenter (DC) capacity to reduce carbon emissions. With hyperscale datacenters exceeding 100 MW individually, and in some grids exceeding 15% of power load, DC adaptation is large enough to harm power grid dynamics, increasing carbon emissions, power prices, or reduce grid reliability. To avoid harm, we explore coordination of DC capacity change varying scope in space and time. In space, coordination scope spans a single datacenter, a group of datacenters, and datacenters with the grid. In time, scope ranges from online to day-ahead. We also consider what DC and grid information is used (e.g. real-time and day-ahead average carbon, power price, and compute backlog). For example, in our proposed PlanShare scheme, each datacenter uses day-ahead information to create a capacity plan and shares it, allowing global grid optimization (over all loads, over entire day). We evaluate DC carbon emissions reduction. Results show that local coordination scope fails to reduce carbon emissions significantly (3.2%--5.4% reduction). Expanding coordination scope to a set of datacenters improves slightly (4.9%--7.3%). PlanShare, with grid-wide coordination and full-day capacity planning, performs the best. PlanShare reduces DC emissions by 11.6%--12.6%, 1.56x--1.26x better than the best local, online approach's results. PlanShare also achieves lower cost. We expect these advantages to increase as renewable generation in power grids increases. Further, a known full-day DC capacity plan provides a stable target for DC resource management.
Key facts. Cited by 6 papers in the map (data through 14 Oct 2026). First posted on arXiv 9 Jan 2023.
Builds on
No reference list yet.
Built on by
Citing papers per year: 2024: 3; 2025: 0; 2026: 3.
6 papers.
- 2024Offline Energy-Optimal LLM Serving: Workload-Based Energy Models for LLM Inference on Heterogeneous Systemscited by 28
- 2024Beyond Efficiency: Scaling AI Sustainablycited by 8
- 2024Input-Dependent Power Usage in GPUscited by 1
- 2026A Physics-Aware Framework for Short-Term GPU Power Forecasting of AI Data Centerscited by 0
- 2026Certificates without Electrons? Theory and Evidence on Impacts from AI-Driven Power Demandcited by 0
- 2026Toward an Energy-Optimized Operation of Data Centers Located in Wind Farms Using Reinforcement Learningcited by 0
- 2026Toward an Energy-Optimized Operation of Data Centers Located in Wind Farms Using Reinforcement Learning29 Jun 2026
- 2026Certificates without Electrons? Theory and Evidence on Impacts from AI-Driven Power Demand30 May 2026
- 2026A Physics-Aware Framework for Short-Term GPU Power Forecasting of AI Data Centers14 Apr 2026
- 2024Input-Dependent Power Usage in GPUs26 Sep 2024
- 2024Offline Energy-Optimal LLM Serving: Workload-Based Energy Models for LLM Inference on Heterogeneous Systems4 Jul 2024
- 2024Beyond Efficiency: Scaling AI Sustainably8 Jun 2024