ECG Artifact Removal from Single-Channel Surface EMG Using Fully Convolutional Networks
Not on the map. Why?
Abstract (arXiv)
Electrocardiogram (ECG) artifact contamination often occurs in surface electromyography (sEMG) applications when the measured muscles are in proximity to the heart. Previous studies have developed and proposed various methods, such as high-pass filtering, template subtraction and so forth. However, these methods remain limited by the requirement of reference signals and distortion of original sEMG. This study proposed a novel denoising method to eliminate ECG artifacts from the single-channel sEMG signals using fully convolutional networks (FCN). The proposed method adopts a denoise autoencoder structure and powerful nonlinear mapping capability of neural networks for sEMG denoising. We compared the proposed approach with conventional approaches, including high-pass filters and template subtraction, on open datasets called the Non-Invasive Adaptive Prosthetics database and MIT-BIH normal sinus rhythm database. The experimental results demonstrate that the FCN outperforms conventional methods in sEMG reconstruction quality under a wide range of signal-to-noise ratio inputs.
Key facts. Cited by 7 papers in the map (data through 7 Oct 2026). Builds on 8 of its 37 references that are in the map. First posted on arXiv 24 Oct 2022.
Builds on
8 of 37 references.
References · 8
- 2014Fully Convolutional Networks for Semantic Segmentationcited by 4,845
- 2016Medical image denoising using convolutional denoising autoencoderscited by 76
- 2019T-GSA: Transformer with Gaussian-weighted self-attention for speech enhancementcited by 34
- 2020EEGdenoiseNet: A benchmark dataset for end-to-end deep learning solutions of EEG denoisingcited by 31
- 2017Raw Waveform-based Speech Enhancement by Fully Convolutional Networkscited by 24
- 2018Deep Recurrent Neural Networks for ECG Signal Denoisingcited by 14
- 2014Feature Learning from Incomplete EEG with Denoising Autoencodercited by 13
- 2021EEGDnet: Fusing Non-Local and Local Self-Similarity for 1-D EEG Signal Denoising with 2-D Transformercited by 11
Built on by
Citing papers per year: 2024: 4; 2025: 0; 2026: 3.
7 papers.
- 2024TrustEMG-Net: Using Representation-Masking Transformer with U-Net for Surface Electromyography Enhancementcited by 6
- 2024SDEMG: Score-based Diffusion Model for Surface Electromyographic Signal Denoisingcited by 5
- 2024MSEMG: Surface Electromyography Denoising with a Mamba-based Efficient Networkcited by 2
- 2024A Non-Intrusive Neural Quality Assessment Model for Surface Electromyography Signalscited by 1
- 2026Cyclostationary Phase Conditioning for Medical Time Series Diffusioncited by 1
- 2026SSEMG-Net: A Spectrogram-Based Mamba Network for Surface Electromyography Denoisingcited by 0
- 2026Prism-SQA: An Interpretable and Adaptable Neural Framework for Surface Electromyography Quality Assessmentcited by 0
- 2026Cyclostationary Phase Conditioning for Medical Time Series Diffusion28 Sep 2026
- 2026Prism-SQA: An Interpretable and Adaptable Neural Framework for Surface Electromyography Quality Assessment11 Sep 2026
- 2026SSEMG-Net: A Spectrogram-Based Mamba Network for Surface Electromyography Denoising10 Sep 2026
- 2024MSEMG: Surface Electromyography Denoising with a Mamba-based Efficient Network28 Nov 2024
- 2024TrustEMG-Net: Using Representation-Masking Transformer with U-Net for Surface Electromyography Enhancement4 Oct 2024
- 2024A Non-Intrusive Neural Quality Assessment Model for Surface Electromyography Signals8 Feb 2024
- 2024SDEMG: Score-based Diffusion Model for Surface Electromyographic Signal Denoising6 Feb 2024