mlsanityData to 7 Oct 2026

SparseAlign: A Super-Resolution Algorithm for Automatic Marker Localization and Deformation Estimation in Cryo-Electron Tomography

arXiv 2201.08706 ↗First posted 21 Jan 2022eess.IV cs.CV cs.NAcited by 0

Not on the map. Why?

Abstract (arXiv)

Tilt-series alignment is crucial to obtaining high-resolution reconstructions in cryo-electron tomography. Beam-induced local deformation of the sample is hard to estimate from the low-contrast sample alone, and often requires fiducial gold bead markers. The state-of-the-art approach for deformation estimation uses (semi-)manually labelled marker locations in projection data to fit the parameters of a polynomial deformation model. Manually-labelled marker locations are difficult to obtain when data are noisy or markers overlap in projection data. We propose an alternative mathematical approach for simultaneous marker localization and deformation estimation by extending a grid-free super-resolution algorithm first proposed in the context of single-molecule localization microscopy. Our approach does not require labelled marker locations; instead, we use an image-based loss where we compare the forward projection of markers with the observed data. We equip this marker localization scheme with an additional deformation estimation component and solve for a reduced number of deformation parameters. Using extensive numerical studies on marker-only samples, we show that our approach automatically finds markers and reliably estimates sample deformation without labelled marker data. We further demonstrate the applicability of our approach for a broad range of model mismatch scenarios, including experimental electron tomography data of gold markers on ice.

Key facts. No citing papers in the map yet (data through 7 Oct 2026). Builds on 3 of its 30 references that are in the map. First posted on arXiv 21 Jan 2022.

Builds on

3 of 30 references.

References · 3

  1. 2015The Alternating Descent Conditional Gradient Method for Sparse Inverse Problemscited by 11
  2. 2019A complete data processing workflow for CryoET and subtomogram averagingcited by 5
  3. 2020Atomic Super-Resolution Tomographycited by 1

Built on by

Not cited yet.