Deep Ultrasound Denoising Without Clean Data
Not on the map. Why?
Abstract (arXiv)
On one hand, the transmitted ultrasound beam gets attenuated as propagates through the tissue. On the other hand, the received Radio-Frequency (RF) data contains an additive Gaussian noise which is brought about by the acquisition card and the sensor noise. These two factors lead to a decreasing Signal to Noise Ratio (SNR) in the RF data with depth, effectively rendering deep regions of B-Mode images highly unreliable. There are three common approaches to mitigate this problem. First, increasing the power of transmitted beam which is limited by safety threshold. Averaging consecutive frames is the second option which not only reduces the framerate but also is not applicable for moving targets. And third, reducing the transmission frequency, which deteriorates spatial resolution. Many deep denoising techniques have been developed, but they often require clean data for training the model, which is usually only available in simulated images. Herein, a deep noise reduction approach is proposed which does not need clean training target. The model is constructed between noisy input-output pairs, and the training process interestingly converges to the clean image that is the average of noisy pairs. Experimental results on real phantom as well as ex vivo data confirm the efficacy of the proposed method for noise cancellation.
Key facts. Cited by 6 papers in the map (data through 7 Oct 2026). First posted on arXiv 7 Jan 2022.
Builds on
No reference list yet.
Built on by
Citing papers per year: 2022: 1; 2023: 1; 2024: 1; 2025: 3.
6 papers.
- 2022Diffusion Models for Medical Image Analysis: A Comprehensive Surveycited by 269
- 2023Deep Ultrasound Denoising Using Diffusion Probabilistic Modelscited by 12
- 2024Diffusion as Sound Propagation: Physics-inspired Model for Ultrasound Image Generationcited by 9
- 2025Speckle2Self: Self-Supervised Ultrasound Speckle Reduction Without Clean Datacited by 9
- 2025Self-supervised Deep Learning for Denoising in Ultrasound Microvascular Imagingcited by 2
- 2025Lightweight Physics-Aware Zero-Shot Ultrasound Plane-Wave Denoisingcited by 1
- 2025Speckle2Self: Self-Supervised Ultrasound Speckle Reduction Without Clean Data9 Jul 2025
- 2025Self-supervised Deep Learning for Denoising in Ultrasound Microvascular Imaging7 Jul 2025
- 2025Lightweight Physics-Aware Zero-Shot Ultrasound Plane-Wave Denoising26 Jun 2025
- 2024Diffusion as Sound Propagation: Physics-inspired Model for Ultrasound Image Generation7 Jul 2024
- 2023Deep Ultrasound Denoising Using Diffusion Probabilistic Models12 Jun 2023
- 2022Diffusion Models for Medical Image Analysis: A Comprehensive Survey14 Nov 2022