mlsanityData to 14 Oct 2026

Fully automatic integration of dental CBCT images and full-arch intraoral impressions with stitching error correction via individual tooth segmentation and identification

arXiv 2112.01784 ↗First posted 3 Dec 2021eess.IV cs.CVcited by 5

Not on the map. Why?

Abstract (arXiv)

We present a fully automated method of integrating intraoral scan (IOS) and dental cone-beam computerized tomography (CBCT) images into one image by complementing each image's weaknesses. Dental CBCT alone may not be able to delineate precise details of the tooth surface due to limited image resolution and various CBCT artifacts, including metal-induced artifacts. IOS is very accurate for the scanning of narrow areas, but it produces cumulative stitching errors during full-arch scanning. The proposed method is intended not only to compensate the low-quality of CBCT-derived tooth surfaces with IOS, but also to correct the cumulative stitching errors of IOS across the entire dental arch. Moreover, the integration provide both gingival structure of IOS and tooth roots of CBCT in one image. The proposed fully automated method consists of four parts; (i) individual tooth segmentation and identification module for IOS data (TSIM-IOS); (ii) individual tooth segmentation and identification module for CBCT data (TSIM-CBCT); (iii) global-to-local tooth registration between IOS and CBCT; and (iv) stitching error correction of full-arch IOS. The experimental results show that the proposed method achieved landmark and surface distance errors of 112.4 μm and 301.7 μm, respectively.

Key facts. Cited by 5 papers in the map (data through 14 Oct 2026). Builds on 4 of its 45 references that are in the map. First posted on arXiv 3 Dec 2021.

Builds on

4 of 45 references.

References · 4

  1. 2015You Only Look Once: Unified, Real-Time Object Detectioncited by 4,852
  2. 2018Dynamic Graph CNN for Learning on Point Cloudscited by 2,223
  3. 2021A fully automated method for 3D individual tooth identification and segmentation in dental CBCTcited by 18
  4. 2019Automatic Registration between Cone-Beam CT and Scanned Surface via Deep-Pose Regression Neural Networks and Clustered Similaritiescited by 4

Built on by

Cited by year (2026 to 14 Oct)

Citing papers per year: 2023: 2; 2024: 0; 2025: 2; 2026: 1.