Volumetric Parameterization of the Placenta to a Flattened Template
Not on the map. Why?
Abstract (arXiv)
We present a volumetric mesh-based algorithm for parameterizing the placenta to a flattened template to enable effective visualization of local anatomy and function. MRI shows potential as a research tool as it provides signals directly related to placental function. However, due to the curved and highly variable in vivo shape of the placenta, interpreting and visualizing these images is difficult. We address interpretation challenges by mapping the placenta so that it resembles the familiar ex vivo shape. We formulate the parameterization as an optimization problem for mapping the placental shape represented by a volumetric mesh to a flattened template. We employ the symmetric Dirichlet energy to control local distortion throughout the volume. Local injectivity in the mapping is enforced by a constrained line search during the gradient descent optimization. We validate our method using a research study of 111 placental shapes extracted from BOLD MRI images. Our mapping achieves sub-voxel accuracy in matching the template while maintaining low distortion throughout the volume. We demonstrate how the resulting flattening of the placenta improves visualization of anatomy and function. Our code is freely available at https://github.com/mabulnaga/placenta-flattening .
Key facts. Cited by 4 papers in the map (data through 7 Oct 2026). Builds on 2 of its 66 references that are in the map. First posted on arXiv 15 Nov 2021.
Builds on
2 of 66 references.
References · 2
- 2018Reversible Harmonic Maps between Discrete Surfacescited by 19
- 2019Placental Flattening via Volumetric Parameterizationcited by 7
Built on by
Citing papers per year: 2022: 2; 2023: 1; 2024: 0; 2025: 0; 2026: 1.
4 papers.
- 2022Automatic Segmentation of the Placenta in BOLD MRI Time Seriescited by 5
- 2022Symmetric Volume Maps: Order-Invariant Volumetric Mesh Correspondence with Free Boundarycited by 2
- 2023Shape-aware Segmentation of the Placenta in BOLD Fetal MRI Time Seriescited by 0
- 2026Volumetrically Consistent Implicit Atlas Learning via Neural Diffeomorphic Flow for Placenta MRIcited by 0
- 2026Volumetrically Consistent Implicit Atlas Learning via Neural Diffeomorphic Flow for Placenta MRI17 Mar 2026
- 2023Shape-aware Segmentation of the Placenta in BOLD Fetal MRI Time Series8 Dec 2023
- 2022Automatic Segmentation of the Placenta in BOLD MRI Time Series4 Aug 2022
- 2022Symmetric Volume Maps: Order-Invariant Volumetric Mesh Correspondence with Free Boundary5 Feb 2022