Leveraging blur information for plenoptic camera calibration
Not on the map. Why?
Abstract (arXiv)
This paper presents a novel calibration algorithm for plenoptic cameras, especially the multi-focus configuration, where several types of micro-lenses are used, using raw images only. Current calibration methods rely on simplified projection models, use features from reconstructed images, or require separated calibrations for each type of micro-lens. In the multi-focus configuration, the same part of a scene will demonstrate different amounts of blur according to the micro-lens focal length. Usually, only micro-images with the smallest amount of blur are used. In order to exploit all available data, we propose to explicitly model the defocus blur in a new camera model with the help of our newly introduced Blur Aware Plenoptic (BAP) feature. First, it is used in a pre-calibration step that retrieves initial camera parameters, and second, to express a new cost function to be minimized in our single optimization process. Third, it is exploited to calibrate the relative blur between micro-images. It links the geometric blur, i.e., the blur circle, to the physical blur, i.e., the point spread function. Finally, we use the resulting blur profile to characterize the camera's depth of field. Quantitative evaluations in controlled environment on real-world data demonstrate the effectiveness of our calibrations.
Key facts. Cited by 7 papers in the map (data through 14 Oct 2026). Builds on 4 of its 58 references that are in the map. First posted on arXiv 9 Nov 2021.
Builds on
4 of 58 references.
References · 4
- 2020Blur Aware Calibration of Multi-Focus Plenoptic Cameracited by 7
- 2018A Generic Multi-Projection-Center Model and Calibration Method for Light Field Camerascited by 6
- 2020Baseline and Triangulation Geometry in a Standard Plenoptic Cameracited by 6
- 2016Unconstrained Two-parallel-plane Model for Focused Plenoptic Cameras Calibrationcited by 2
Built on by
Citing papers per year: 2023: 1; 2024: 2; 2025: 3; 2026: 1.
7 papers.
- 2024LiFCal: Online Light Field Camera Calibration via Bundle Adjustmentcited by 4
- 2023Blur aware metric depth estimation with multi-focus plenoptic camerascited by 1
- 2025LiFMCR: Dataset and Benchmark for Light Field Multi-Camera Registrationcited by 1
- 2024Mind the Exit Pupil Gap: Revisiting the Intrinsics of a Standard Plenoptic Cameracited by 0
- 2025A Linear Fractional Transformation Model and Calibration Method for Light Field Cameracited by 0
- 2025CircleFlow: Flow-Guided Camera Blur Estimation using a Circle Grid Targetcited by 0
- 2026PRISM-VO: Scale-Aware Visual Odometry Using Photometric Plenoptic Bundle Adjustmentcited by 0
- 2026PRISM-VO: Scale-Aware Visual Odometry Using Photometric Plenoptic Bundle Adjustment30 Jun 2026
- 2025CircleFlow: Flow-Guided Camera Blur Estimation using a Circle Grid Target30 Nov 2025
- 2025A Linear Fractional Transformation Model and Calibration Method for Light Field Camera6 Nov 2025
- 2025LiFMCR: Dataset and Benchmark for Light Field Multi-Camera Registration15 Oct 2025
- 2024LiFCal: Online Light Field Camera Calibration via Bundle Adjustment21 Aug 2024
- 2024Mind the Exit Pupil Gap: Revisiting the Intrinsics of a Standard Plenoptic Camera20 Feb 2024
- 2023Blur aware metric depth estimation with multi-focus plenoptic cameras8 Aug 2023