Localization and Control of Magnetic Suture Needles in Cluttered Surgical Site with Blood and Tissue
Not on the map. Why?
Abstract (arXiv)
Real-time visual localization of needles is necessary for various surgical applications, including surgical automation and visual feedback. In this study we investigate localization and autonomous robotic control of needles in the context of our magneto-suturing system. Our system holds the potential for surgical manipulation with the benefit of minimal invasiveness and reduced patient side effects. However, the non-linear magnetic fields produce unintuitive forces and demand delicate position-based control that exceeds the capabilities of direct human manipulation. This makes automatic needle localization a necessity. Our localization method combines neural network-based segmentation and classical techniques, and we are able to consistently locate our needle with 0.73 mm RMS error in clean environments and 2.72 mm RMS error in challenging environments with blood and occlusion. The average localization RMS error is 2.16 mm for all environments we used in the experiments. We combine this localization method with our closed-loop feedback control system to demonstrate the further applicability of localization to autonomous control. Our needle is able to follow a running suture path in (1) no blood, no tissue; (2) heavy blood, no tissue; (3) no blood, with tissue; and (4) heavy blood, with tissue environments. The tip position tracking error ranges from 2.6 mm to 3.7 mm RMS, opening the door towards autonomous suturing tasks.
Key facts. Cited by 1 paper in the map (data through 14 Oct 2026). Builds on 9 of its 28 references that are in the map. First posted on arXiv 20 May 2021.
Builds on
9 of 28 references.
References · 9
- 2015Deep Residual Learning for Image Recognitioncited by 52,096
- 2019PyTorch: An Imperative Style, High-Performance Deep Learning Librarycited by 20,305
- 2015U-Net: Convolutional Networks for Biomedical Image Segmentationcited by 19,713
- 2018MobileNetV2: Inverted Residuals and Linear Bottleneckscited by 4,795
- 2016V-Net: Fully Convolutional Neural Networks for Volumetric Medical Image Segmentationcited by 2,292
- 2017Rethinking Atrous Convolution for Semantic Image Segmentationcited by 2,161
- 2017Generalised Dice overlap as a deep learning loss function for highly unbalanced segmentationscited by 620
- 2016ENet: A Deep Neural Network Architecture for Real-Time Semantic Segmentationcited by 291
- 2019Attention-Guided Lightweight Network for Real-Time Segmentation of Robotic Surgical Instrumentscited by 15
Built on by
Citing papers per year: 2026: 1.
1 paper.