Oversampling errors in multimodal medical imaging are due to the Gibbs effect

arXiv 2103.05964 ↗First posted 10 Mar 2021math.NA cs.CV cs.NAcited by 2

Not on the map. Why?

Abstract (arXiv)

To analyse multimodal 3-dimensional medical images, interpolation is required for resampling which - unavoidably - introduces an interpolation error. In this work we consider three segmented 3-dimensional images resampled with three different neuroimaging software tools for comparing undersampling and oversampling strategies and to identify where the oversampling error lies. The results indicate that undersampling to the lowest image size is advantageous in terms of mean value per segment errors and that the oversampling error is larger where the gradient is steeper, showing a Gibbs effect.