A signal detection model for quantifying over-regularization in non-linear image reconstruction
Not on the map. Why?
Abstract (arXiv)
Purpose: Many useful image quality metrics for evaluating linear image reconstruction techniques do not apply to or are difficult to interpret for non-linear image reconstruction. The vast majority of metrics employed for evaluating non-linear image reconstruction are based on some form of global image fidelity, such as image root mean square error (RMSE). Use of such metrics can lead to over-regularization in the sense that they can favor removal of subtle details in the image. To address this shortcoming, we develop an image quality metric based on signal detection that serves as a surrogate to the qualitative loss of fine image details. Methods: The metric is demonstrated in the context of a breast CT simulation, where different equal-dose configurations are considered. The configurations differ in the number of projections acquired. Image reconstruction is performed with a non-linear algorithm based on total variation constrained least-squares (TV-LSQ). The images are evaluated visually, with image RMSE, and with the proposed signal-detection based metric. The latter uses a small signal, and computes detectability in the sinogram and in the reconstructed image. Loss of signal detectability through the image reconstruction process is taken as a quantitative measure of loss of fine details in the image. Results: Loss of signal detectability is seen to correlate well with the blocky or patchy appearance due to over-regularization with TV-LSQ, and this trend runs counter to the image RMSE metric, which tends to favor the over-regularized images. Conclusions: The proposed signal detection based metric provides an image quality assessment that is complimentary to that of image RMSE. Using the two metrics in concert may yield a useful prescription for determining CT algorithm and configuration parameters when non-linear image reconstruction is used.
Key facts. Cited by 3 papers in the map (data through 7 Oct 2026). First posted on arXiv 7 Oct 2020.
Builds on
No reference list yet.
Built on by
Citing papers per year: 2023: 1; 2024: 1; 2025: 1.
3 papers.
- 2023Ideal Observer Computation by Use of Markov-Chain Monte Carlo with Generative Adversarial Networkscited by 6
- 2024Enhancing signal detectability in learning-based CT reconstruction with a model observer inspired loss functioncited by 2
- 2025Task-based Regularization in Penalized Least-Squares for Binary Signal Detection Tasks in Medical Image Denoisingcited by 0
- 2025Task-based Regularization in Penalized Least-Squares for Binary Signal Detection Tasks in Medical Image Denoising30 Jan 2025
- 2024Enhancing signal detectability in learning-based CT reconstruction with a model observer inspired loss function15 Feb 2024
- 2023Ideal Observer Computation by Use of Markov-Chain Monte Carlo with Generative Adversarial Networks2 Apr 2023