iPhantom: a framework for automated creation of individualized computational phantoms and its application to CT organ dosimetry
Not on the map. Why?
Abstract (arXiv)
Objective: This study aims to develop and validate a novel framework, iPhantom, for automated creation of patient-specific phantoms or digital-twins (DT) using patient medical images. The framework is applied to assess radiation dose to radiosensitive organs in CT imaging of individual patients. Method: From patient CT images, iPhantom segments selected anchor organs (e.g. liver, bones, pancreas) using a learning-based model developed for multi-organ CT segmentation. Organs challenging to segment (e.g. intestines) are incorporated from a matched phantom template, using a diffeomorphic registration model developed for multi-organ phantom-voxels. The resulting full-patient phantoms are used to assess organ doses during routine CT exams. Result: iPhantom was validated on both the XCAT (n=50) and an independent clinical (n=10) dataset with similar accuracy. iPhantom precisely predicted all organ locations with good accuracy of Dice Similarity Coefficients (DSC) >0.6 for anchor organs and DSC of 0.3-0.9 for all other organs. iPhantom showed less than 10% dose errors for the majority of organs, which was notably superior to the state-of-the-art baseline method (20-35% dose errors). Conclusion: iPhantom enables automated and accurate creation of patient-specific phantoms and, for the first time, provides sufficient and automated patient-specific dose estimates for CT dosimetry. Significance: The new framework brings the creation and application of CHPs to the level of individual CHPs through automation, achieving a wider and precise organ localization, paving the way for clinical monitoring, and personalized optimization, and large-scale research.
Key facts. Cited by 5 papers in the map (data through 7 Oct 2026). First posted on arXiv 20 Aug 2020.
Builds on
No reference list yet.
Built on by
Citing papers per year: 2022: 2; 2023: 2; 2024: 1.
5 papers.
- 2023The stochastic digital human is now enrolling for in silico imaging trials -- Methods and tools for generating digital cohortscited by 6
- 2022Virtual vs. Reality: External Validation of COVID-19 Classifiers using XCAT Phantoms for Chest Computed Tomographycited by 3
- 2022Quality or Quantity: Toward a Unified Approach for Multi-organ Segmentation in Body CTcited by 0
- 2023Scout-Net: Prospective Personalized Estimation of CT Organ Doses from Scout Viewscited by 0
- 2024XCAT-3.0: A Comprehensive Library of Personalized Digital Twins Derived from CT Scanscited by 0
- 2024XCAT-3.0: A Comprehensive Library of Personalized Digital Twins Derived from CT Scans18 May 2024
- 2023Scout-Net: Prospective Personalized Estimation of CT Organ Doses from Scout Views23 Dec 2023
- 2023The stochastic digital human is now enrolling for in silico imaging trials -- Methods and tools for generating digital cohorts20 Jan 2023
- 2022Virtual vs. Reality: External Validation of COVID-19 Classifiers using XCAT Phantoms for Chest Computed Tomography7 Mar 2022
- 2022Quality or Quantity: Toward a Unified Approach for Multi-organ Segmentation in Body CT3 Mar 2022