Topology design of two-fluid heat exchange

arXiv 2005.08870 ↗First posted 5 May 2020cs.CEcited by 1

Not on the map. Why?

Abstract (arXiv)

Heat exchangers are devices that typically transfer heat between two fluids. The performance of a heat exchanger such as heat transfer rate and pressure loss strongly depends on the flow regime in the heat transfer system. In this paper, we present a density-based topology optimization method for a two-fluid heat exchange system, which achieves a maximum heat transfer rate under fixed pressure loss. We propose a representation model accounting for three states, i.e., two fluids and a solid wall between the two fluids, by using a single design variable field. The key aspect of the proposed model is that mixing of the two fluids can be essentially prevented without any penalty scheme. This is because the solid constantly exists between the two fluids due to the use of the single design variable field. We demonstrate the effectiveness of the proposed approach through three-dimensional numerical examples in which an optimized design is compared with a simple reference design, and the effects of design conditions (i.e., Reynolds number, Prandtl number, design domain size, and flow arrangements) are investigated.

Key facts. Cited by 1 paper in the map (data through 14 Oct 2026). First posted on arXiv 5 May 2020.

Builds on

No reference list yet.

Built on by

Cited by year

Citing papers per year: 2025: 1.

1 paper.