mlsanityData to 14 Oct 2026

EMG wrist-hand motion recognition system for real-time Embedded platform

arXiv 1903.06764 ↗First posted 15 Mar 2019eess.SPcited by 1

Not on the map. Why?

Abstract (arXiv)

Electromyography (EMG) signal analysis is a popular method for controlling prosthetic and gesture control equipment. For portable systems, such as prosthetic limbs, real-time low-power operation on embedded processors is critical, but to date, there has been no record of how existing EMG analysis approaches support such deployments. This paper presents a novel approach to time-domain classification of multi-channel EMG signals harnessed from randomly-placed sensors according to the wrist-hand movements which caused their occurrence. It shows how, by employing a very small set of time-domain features, Kernel Fisher discriminant feature projection and Radial Bias Function neural network classifiers, nine wrist-hand movements can be detected with accuracy exceeding 99% - surpassing the state-of-the-art on record. It also shows how, when deployed on ARM Cortex-A53, the processing time is not only sufficient to enable real-time processing but is also a factor 50 shorter than the leading time-frequency techniques on record.

Key facts. Cited by 1 paper in the map (data through 14 Oct 2026). First posted on arXiv 15 Mar 2019.

Builds on

No reference list yet.

Built on by

Cited by year (2026 to 14 Oct)

Citing papers per year: 2026: 1.

1 paper.