mlsanityData to 7 Oct 2026

Optimization methods for MR image reconstruction (long version)

arXiv 1903.03510 ↗First posted 8 Mar 2019eess.IV math.OCcited by 3

Not on the map. Why?

Abstract (arXiv)

The development of compressed sensing methods for magnetic resonance (MR) image reconstruction led to an explosion of research on models and optimization algorithms for MR imaging (MRI). Roughly 10 years after such methods first appeared in the MRI literature, the U.S. Food and Drug Administration (FDA) approved certain compressed sensing methods for commercial use, making compressed sensing a clinical success story for MRI. This review paper summarizes several key models and optimization algorithms for MR image reconstruction, including both the type of methods that have FDA approval for clinical use, as well as more recent methods being considered in the research community that use data-adaptive regularizers. Many algorithms have been devised that exploit the structure of the system model and regularizers used in MRI; this paper strives to collect such algorithms in a single survey. Many of the ideas used in optimization methods for MRI are also useful for solving other inverse problems.

Key facts. Cited by 3 papers in the map (data through 7 Oct 2026). First posted on arXiv 8 Mar 2019.

Builds on

No reference list yet.

Built on by

Cited by year (2026 to 7 Oct)

Citing papers per year: 2022: 1; 2023: 1; 2024: 0; 2025: 0; 2026: 1.

3 papers.