Dental pathology detection in 3D cone-beam CT
Not on the map. Why?
Abstract (arXiv)
Cone-beam computed tomography (CBCT) is a valuable imaging method in dental diagnostics that provides information not available in traditional 2D imaging. However, interpretation of CBCT images is a time-consuming process that requires a physician to work with complicated software. In this work we propose an automated pipeline composed of several deep convolutional neural networks and algorithmic heuristics. Our task is two-fold: a) find locations of each present tooth inside a 3D image volume, and b) detect several common tooth conditions in each tooth. The proposed system achieves 96.3% accuracy in tooth localization and an average of 0.94 AUROC for 6 common tooth conditions.
Key facts. Cited by 1 paper in the map (data through 14 Oct 2026). First posted on arXiv 24 Oct 2018.
Builds on
No reference list yet.
Built on by
Citing papers per year: 2024: 1.